FENCE RULES – DYER (TOWN), INDIANA
OVERVIEW
This page applies to single-family residential fence projects within the municipal boundaries of the Town of Dyer in Lake County, Indiana. Dyer administers its own zoning and building requirements. County-regulated drains have a separate Lake County review process where those drains affect the property.
Dyer limits residential fences to six feet, but a required front yard follows a more restrictive decorative-fence rule. The Zoning Administrator must approve the decorative purpose and safety of a front-yard proposal; split rail, picket and wrought iron have different published height limits. The Town’s building and zoning application includes fences, and pool enclosures have their own local height and safety-cover provisions. A fence location also depends on the legal property boundary, recorded plat and easements, drainage swales, and any applicable floodplain or regulated-drain requirements. Wood, vinyl/PVC and chain-link receive different treatment in the ordinance’s definitions and front-yard provisions. Updated October 2026.
| Quick question | Dyer answer |
|---|---|
| Permit or approval | The Town’s building and zoning application expressly includes fences. Decorative front-yard fences require a Zoning Administrator determination. Pool, floodplain and drainage approvals can also apply. |
| Typical fence height | Residential maximum: 6 feet. Approved decorative front-yard examples: split rail up to 48 inches; picket or wrought iron up to 36 inches. |
| Placement & property lines | Front-yard restrictions apply. Locate the legal boundary and recorded easements, keep drainageways open, and satisfy any applicable floodplain or regulated-drain conditions. |
| Common fence materials | Wood: named in the fence definition. Vinyl/PVC: the definition names the broader category of plastic; vinyl and PVC are not named separately. Chain-link: slatted chain-link is addressed in the solid-fence definition. Front-yard decorative restrictions apply separately. |
| Important local conditions | Fence rules may be further affected by decorative front-yard review, recorded subdivision conditions, drainage and utility easements, County-regulated drains, floodplain or floodway location, and use as a pool enclosure. |
| Official local resource | Town of Dyer Building and Zoning Application |
The table is for quick reference; the corresponding sections below explain the additional details. Before purchasing materials or beginning construction, read the sections that apply to the property, review the linked official sources, and confirm site-specific questions with the Dyer Building Department, Zoning Administrator, or the responsible drainage or floodplain office identified below.
GOVERNANCE
The Town Council adopts Dyer’s local ordinances. The Dyer zoning and subdivision code contains the general fence division in Sections 10-175 through 10-180, private-pool requirements in Section 10-127, and zoning administration in Section 10-133. The Building Commissioner and Zoning Administrator administer and enforce zoning requirements. The Building Department publishes the building and zoning application and administers local construction review.
The Dyer Plan Commission operates under Indiana’s advisory planning framework and reviews subdivision plats within the Town. Recorded plats can establish continuing drainage, easement and hazard-fencing conditions. Public subdivision requirements are separate from an association’s private architectural rules.
The Stormwater Administrator serves as Dyer’s Floodplain Administrator. The Town’s Stormwater Management Board administers relevant local drainage approvals. Where a project affects a County-regulated drain, the Lake County Surveyor and Lake County Drainage Board have separate responsibilities under the Indiana Drainage Code and County drainage requirements.
Indiana’s substantive residential building rules apply statewide within their scope. The currently effective residential code is the 2020 Indiana Residential Code, adopting the 2018 International Residential Code with Indiana amendments. Local building and zoning administration remains part of the Dyer approval process.
PERMIT AND APPROVAL REQUIREMENTS
Fences are expressly included in the scope of Dyer’s Building Code, and the Town’s Building and Zoning Application contains a fence entry. The application asks for fence lineal feet, square feet and cost, together with the job location, subdivision and lot, description of work, owner and contractor information, and the applicant’s signature.
• Building and zoning permit provisions: Section 10-133(b) requires a permit from the Building Commissioner before a building or other structure is erected, moved, added to, or structurally altered. Section 7-56 separately states that a permit must be obtained before construction, alteration or repair of a building or structure costing more than $1,000. The two provisions state different scopes; the zoning provision does not contain that dollar threshold.
• Plans and zoning compliance: Section 7-55 requires a plat or sketch showing the proposed location and lot boundaries, with plans and specifications describing the work. Section 10-133(c) requires application for a Certificate of Zoning Compliance and issuance of a Temporary Certificate before the permit is issued. Its application requirements include plans in triplicate, drawn to scale, showing the lot’s dimensions and shape, existing buildings, and proposed work. Additional information may be required to determine conformity with the ordinance. A State Design Release is required only for construction covered by that separate state process.
• Fences on unsubdivided lots: Section 10-133(c) lists fences among the exceptions to its restriction on issuing building permits only for subdivided lots. The fence permit and other applicable requirements remain part of the approval process.
• Certificates, timing and approved work: A Final Certificate of Zoning Compliance follows completion. A Temporary Certificate may be issued for no more than 12 months, subject to conditions and safeguards. An improvement-location permit expires if work has not begun within 90 days. For approved work valued below $600,000, the stated substantial-completion period is one year; for work exceeding $600,000, the stated permit term is two years. Permits and certificates authorize only the use, arrangement and construction shown in the approved application and plans. Section 10-119 lists a $10 residential Certificate of Zoning Compliance fee; other applicable permit fees are separate.
• Decorative front-yard fences: The Zoning Administrator must find that the proposed fence is decorative only, will not obstruct clear vision, and will not create a safety hazard through its construction or location. The specific height branches appear below.
• Special flood hazard areas: A local floodplain development permit is required before development in an applicable special flood hazard area. The development definition expressly includes erection of walls and fences. The Floodplain Administrator administers this review; floodway projects also follow the applicable state approval, license or exemption provisions.
• Drainage easements and regulated drains: A crossing or encroachment of a Town drainage easement requires application and acceptance by the Stormwater Management Board. Work affecting a County-regulated drain or its easement follows the separate County Surveyor and Drainage Board process described under placement.
• Covered utility and infrastructure excavation: Dyer’s right-of-way excavation rules require a Town permit and applicable bonds for work within their operative excavation definition, which addresses earthwork, utility-service work and the likelihood of disrupting Town infrastructure. The permit covers a single excavation and includes insurance, training and other application requirements.
Indiana replaces model IRC Section R105 with provisions on additions and alterations. The Indiana residential code does not provide a statewide seven-foot fence permit exemption.
FENCE PLACEMENT RULES
Section 10-175 prohibits a fence in a required front yard in a residential district or along the edge of a front yard unless the Zoning Administrator makes the decorative-purpose and safety findings. A legal property boundary, required yard, street right-of-way and recorded easement describe different limits on a site. The proposed fence location belongs on the permit sketch or plans together with the lot boundaries.
• West U.S. 30 Corridor Special Use District: Section 10-161.3 states that no fence may be located forward of the actual building face. Its Type I and Type II provisions include residential uses, so this placement condition matters for residential property subject to that district.
• Qualifying agricultural partition fences: Indiana Code 32-26-9 applies only if at least one adjoining parcel is agricultural land: land zoned or otherwise designated agricultural, used for crops or livestock, or reserved for conservation. Its coverage includes enclosed or unenclosed, cultivated or uncultivated, wild or wood-lot agricultural land. Section 2 requires a partition fence on the dividing line for property outside, abutting or adjacent to a town or city boundary, regardless of when the properties were divided. For a Dyer property, the municipal-boundary and agricultural conditions must be established before applying this obligation. Within the chapter’s scope, an existing fence used by adjoining owners as a partition fence is maintained and paid for under the chapter unless they agree otherwise.
• Partition-fence shares and agreements: If the owners have not divided responsibility, a north-south boundary assigns the north half to the east owner and the south half to the west owner; an east-west boundary assigns the west half to the north owner and the east half to the south owner. An owner who built the other half and maintained it for at least 5 years may continue maintaining that portion. Construction, rebuilding and repair costs are proportional to the number of rods or share of fence owned along the boundary, including fee-simple and life-estate ownership. Under Indiana Code 32-26-3-1, owners choosing an arrangement different from Article 26 must sign a written agreement and record it in the county or counties containing the properties.
• Partition-fence default process: After completing their own portion, an interested owner gives the defaulting owner, agent or tenant 20 days’ notice to build, rebuild or repair the defaulting portion. If the default continues, the complaining owner notifies the township trustee. The trustee estimates the cost and, within a reasonable time, notifies the defaulting owner of the probable cost. After a further 20 days without the required work, the trustee builds or repairs using only fence materials most commonly used by community farmers. On a township line, the complaining owner’s township trustee has jurisdiction unless disqualified. A trustee who is related to an interested owner or is an interested owner is replaced under the statute by the nearest qualifying other-township trustee; the chapter also specifies the adjoining-township procedure for a disqualified trustee.
• Partition-fence watercourses: Where a crossing ditch or creek adds maintenance expense and the owners cannot agree on shares, the trustee appoints 3 disinterested citizens to apportion the fence. If a ditch or creek marks the boundary and prevents a boundary-line fence, each owner builds and maintains a separate fence on their own land as near the boundary as practical, at their own cost. Where a stationary crossing is impracticable, a continuously connected floodgate or similar structure must be sufficiently high, tight and strong to turn hogs, sheep, cattle, mules, horses or other domestic animals and swing upward during high water. On written notice of disagreement about its design or additional cost, the trustee appoints 3 disinterested township citizens to determine the structure and allocate costs, considering the fence portions maintained by each owner. A majority decision is binding; arbitrators receive $2 each, paid in the assigned cost proportions. If construction or payment remains in default after 30 days, the trustee constructs the structure and collects its cost and arbitrator compensation through the ordinary partition-fence process. Repair, rebuilding and replacement follow that determination.
• Partition-fence cost recovery: After trustee-arranged fence work, a certified statement of actual costs is prepared in 3 copies: for the affected owner, township record and county auditor, with the trustee’s county claim. The auditor examines it and submits it at the commissioners’ next regular meeting. Unless an apparent error exists, the county pays the allowed amount; it is charged against the affected property on the tax duplicate and collected as taxes. Section 5 separately provides for contractor payment from township funds and reimbursement when the contract price reaches the county treasury; the trustee has no personal liability for the chapter’s fence contract. The qualifying agricultural fence specifications appear below.
• Recorded subdivision easements: The subdivision dedication language reserves utility and drainage easements. Within those easements, structures, plantings or other materials may not interfere with utility installation or maintenance, change drainage direction, or obstruct or retard drainage. The lot owner maintains the easement area and improvements except those assigned to a public authority or utility. The property’s recorded plat and easement instruments establish its particular boundaries and conditions.
• Drainage swales and channels: Section 7-38 expressly prohibits fences, structures, excavation, fill, trees, shrubs and similar impediments from blocking or impeding free surface-water drainage in a swale or channel. Section 10-72 also places responsibility on lot owners to maintain the drainage-related lot grade established by approved engineering plans.
• Town stormwater overflow paths: Dyer’s stormwater management resources explain the separate drainage program. Section 9-82.1 requires permanent drainage easements for the development’s 100-year overflow paths, describing 30 feet along the centerline of the flow path. Fences or landscaping that may impede stormwater flow or maintenance of conveyances require Stormwater Management Board approval. Owners or the designated homeowners’ association maintain those areas.
• Town drainage facility easements: Section 9-82.3 establishes different dimensions for different subdivision facilities. New channels require 25 feet from the top of bank on each side, plus the ditch width. Specified new drainage facilities and drain lines at least 12 inches in diameter require at least a 30-foot easement, 15 feet on each side of centerline; wider easements may be required for deeper pipes. Rear-yard swales and emergency overflow paths require a 30-foot width, 15 feet each side. Detention-facility maintenance easements extend at least 30 feet beyond top of bank, with a 30-foot access easement from public right-of-way unless the facility is immediately beside it. For Town-maintained systems outside subdivisions, the stated easement is 15 feet on each side of channel top of bank or drain centerline, with a 10-foot vegetative filter strip maintained along each bank. Drainage-easement crossings and encroachments require Board acceptance.
• Public subdivision drainage and hazard fencing: Section 10-73 requires perpetual unobstructed drainage easements, including at least 15 feet of width where drainage facilities cannot feasibly occupy street rights-of-way. Watercourse easement widths are determined through subdivision review and, for legal drains, the County Drainage Board. Section 10-72(f) requires a subdivider or developer to install hazard fences when the Plan Commission determines they are needed, using the height and material shown on the final plat, before occupancy certificates issue.
• County-regulated drains: The Lake County stormwater ordinance and technical standards include County-regulated drains within the County’s jurisdiction, including those inside municipalities. Indiana Code 36-9-27-33 establishes a 75-foot right-of-entry corridor, measured at right angles from the centerline of a tiled drain or the top edge of each bank of an open drain, as determined by the surveyor. Permanent structures require written Drainage Board consent. Temporary structures must be removed immediately when ordered; trees, shrubs and woody vegetation have separate written-consent requirements.
• Regulated-drain reductions and County fence treatment: For the specified newer regulated drains and urban drains, the Board may approve reductions to no less than 25 feet from each open bank or 15 feet from tiled-drain centerline. In a platted subdivision, a further tiled-drain reduction requires the surveyor’s recommendation and cannot be less than 7 feet on each side or less than the recommendation. Lake County’s ordinance expressly includes permanent fences in its 75-foot restriction for regulated drains outside platted subdivisions, unless accepted by the Board. Actual approved easements and reductions determine the corridor at a property.
• County regulated-drain applications: The County’s application includes temporary and permanent structures, easement encroachments and easement reductions. It identifies fences among temporary structures subject to removal at the owner’s expense when access is needed. This differs from the state statute’s provision allowing temporary structures without written consent, subject to immediate removal when ordered. The County form requires filing 14 days before the meeting, an explanatory cover letter, plans, a vicinity map, applicable fees and any required agent authorization. It provides for 5 days’ advance written work notice, notice the day before completion, applicable sealed as-built plans within 30 days, and a two-year approval term, subject to the Board’s waiver provisions and review of changes.
• Floodplain and floodway sites: Walls and fences fall within the local floodplain development definition. In a regulatory floodway, Dyer requires DNR approval or evidence of a qualifying state license or exemption before local action. Local permit conditions cannot be less restrictive than the applicable state approval. In a riverine fringe, the local administrator may issue the permit under the local standards. Undelineated floodplain provisions distinguish upstream drainage areas greater than one square mile from those less than one square mile and prescribe DNR referral or engineering analysis accordingly.
• Floodway effects: In FIRM-designated floodways, development must cause no increase in base-flood levels without the prescribed conditional map-revision process; an increase affecting a structure is not permitted through that process. For DNR-identified floodways not yet shown on the effective FIRM, the code applies its cumulative-effects test, including the stated 0.15-foot adverse-effect definition and hydraulic analysis. A qualifying agricultural fence used primarily to keep animals in or out and that does not obstruct water or debris flow has the separate state floodway-permit exemption in Indiana Code 14-28-1-22.5.
• Covered grading and construction-site disturbance: Land alteration affecting contour, runoff, elevation, absorption or drainage follows Dyer’s drainage controls. Published exceptions include qualifying minor residential landscaping, filling small holes caused by removal of posts, and fill less than 1 foot deep on natural terrain flatter than a 10% slope, no more than 50 cubic yards per acre, not intended to support structures and not obstructing drainage. Separate construction-stormwater provisions distinguish disturbance of 1 acre or more, smaller portions of a larger common plan, and other sub-acre work; lots within a larger permitted project follow its approved stormwater pollution prevention plan and applicable individual-lot process.
• Indiana 811 before fence-post digging: Before covered excavation, submit a locate notice through Indiana’s underground-utility locate process. Notice must be received at least 2 full working days and no more than 10 calendar days before work. A working day is 7 a.m. to 6 p.m. Indianapolis time, excluding Saturdays, Sundays and state or national legal holidays. The normal lawful start is no earlier than 7 a.m. on the next working day after two full working days have elapsed following receipt. Earlier work requires qualifying electronic positive responses from all affected operators showing facilities marked or clear. Check utility responses and markings, and provide the required affirmative acknowledgment of receipt through Indiana 811 before starting. Notice expires at 11:59 p.m. Indianapolis time 20 days after its receipt date; unfinished covered digging requires a new request and notice and new affected-operator markings before continuing. The narrow exception applies only to excavation performed solely with hand tools, on property owned or controlled by the person performing it, no deeper than 12 inches.
FENCE HEIGHT AND VISIBILITY RULES
Section 10-177 limits residential fences to a maximum of 6 feet. The general fence division does not establish a separate ordinary side-yard and rear-yard height schedule or a grade-based measurement formula.
• Decorative residential front yards: A required front-yard fence, or fence along the edge of a front yard, requires the Zoning Administrator’s decorative-purpose and safety findings. The published examples are a split-rail fence with total height no greater than 48 inches, a picket fence no greater than 36 inches, or wrought iron no greater than 36 inches. The fence must not obstruct clear vision or create a safety hazard through its construction or location.
• Barbed-wire height: Where barbed wire is permissible, wire added to the top counts toward the fence’s overall height. Its separate residential-district distance restriction appears below.
• Malicious or spite fences: Indiana Code 32-26-10 treats a fence-like structure as a nuisance when it unnecessarily exceeds 6 feet and is maliciously erected or maintained to annoy adjoining owners or occupants. An adjoining owner or occupant injured in comfort or enjoyment may bring a nuisance action for damages, abatement and other preventive remedies. These statutory elements operate separately from Dyer’s zoning limits.
• Residential property in a commercial district: The code states a 6-foot residential fence maximum and separately sets an 8-foot maximum for fences in commercial districts. Commercial districts also have a provision allowing front-yard fences where clear vision is maintained. Dyer permits residential uses in several commercial and mixed-use districts; confirm the applicable residential and district provisions with the Zoning Administrator for that property.
• Private outdoor pool enclosures: Dyer’s local pool provision specifies a wall or fence at least 5 feet and no more than 6 feet, subject to the local safety-cover alternative. Indiana’s residential pool access-control methods have their own dimensions and conditions, explained below.
MATERIAL AND CONSTRUCTION LIMITS
Section 10-120 defines a fence as a boundary, screen, separation, privacy, protection or confinement structure constructed of wood, plastic, metal, masonry and similar materials. Section 10-175 separately controls decorative front-yard designs.
• Wood: Wood is expressly named in the fence definition. Split rail and picket are among the decorative front-yard examples, with their respective height and approval conditions.
• Vinyl/PVC: The general fence provisions do not specifically name vinyl or PVC or provide a separate product-specific standard. The definition uses the broader category of plastic.
• Chain-link and slats: The solid-fence definition specifically states that chain-link with slats is not considered a solid fence. The general fence division does not publish a separate chain-link height standard. The residential maximum and front-yard decorative review apply according to their terms.
• Metal and masonry: Both categories appear in the fence definition. Wrought iron is an express decorative front-yard example, limited to 36 inches and the Zoning Administrator’s required findings.
• Open and solid classifications: An open fence has at least 50% of its superficial surface in regularly distributed openings over its entirety. A solid fence has no distributed openings; shadowbox is classified as solid. These definitions describe the fence form. The general fence division does not prescribe a universal open-area percentage for every residential yard.
• Barbed wire near residential districts: Barbed wire is prohibited on any fence located within 10 feet of a residential district. Where permissible, top wire is included in overall height.
• Ordinary construction details: The general fence division does not specify a finished-side orientation rule, a separate allowance for taller posts or columns, or a fence-and-retaining-wall measurement formula. Approved plans and any applicable recorded plat conditions govern the work authorized for the site.
• Boundary hedges and live fences: Indiana Code 32-26-5 covers a hedge or other live fence grown along the dividing line of properties owned by different people. It requires cutting and trimming once each calendar year to no more than 5 feet high and 3 feet wide. On an adjoining owner’s signed written complaint of neglected trimming, the township trustee examines the live fence within 5 days. If untrimmed, written notice requires trimming and removal of brush to the owner’s property within 30 days after receipt. Notice is read to the owner or left at the usual residence; a nonresident receives a mailed copy at the last known post-office address. If the owner, agent or tenant does not comply, the trustee arranges trimming and brush removal immediately after the 30 days and recovers expenses through a circuit- or superior-court suit in the county where the live fence stands. The prosecuting attorney brings the suit for the State on the trustee’s relation, with a $10 fee collected as suit costs. This rule concerns qualifying boundary vegetation.
• Qualifying agricultural fence construction: Within the agricultural partition-fence scope described under placement, Indiana Code 32-26-9-3(f) recognizes a straight board-and-wire, straight wire, straight board or picket fence 4 feet high; a straight rail fence 4½ feet high; or a worm rail fence 5 feet high. Each must be sufficiently tight and strong to hold cattle, hogs, horses, mules and sheep. The watercourse and floodgate alternatives described above retain their own conditions. These are qualifying partition-fence specifications; Dyer’s applicable zoning and approval requirements remain separate.
• Dyer private outdoor pools: Section 10-127 covers a pool or open tank outside a completely enclosed building that contains or is normally capable of containing water more than 1½ feet deep, under its stated residential-use provisions. The pool or entire property must have a 5-to-6-foot wall or fence preventing uncontrolled access by children from the street or adjoining properties. Pool drainage must avoid runoff onto adjacent property. The local alternative, effective June 1, 2021, is a waterproof pool safety cover capable of supporting at least 485 pounds, covering the pool whenever it is unoccupied and unattended.
• Indiana residential pool access: Indiana R326 defines qualifying residential pools as in-ground or on-ground pools capable of a depth greater than 42 inches, plus pools installed inside a residence regardless of depth, intended for noncommercial use by no more than two owner families and their guests. Artificial lakes are excluded. R326.27.3 permits four access-control methods: a wall or fence at least 4 feet high completely surrounding the pool and deck; other means at least 4 feet high deemed impenetrable by the enforcing authority at construction and surrounding the pool and deck when unused; a combination of those methods; or a compliant power safety pool cover. The first three methods retain the stated self-closing, latching and lockable gate and door conditions.
• Indiana power-cover conditions: The state power-cover alternative requires a continuous connection to the deck that prohibits access when closed; mechanical operation controlled by a key, key and switch, or personal-code touch pad; necessary tracks, rollers, rails, guides and accessories installed to manufacturer instructions; and an identification tag showing compliance with ASTM F 1346-91 (2018) for power safety pool covers. Dyer’s local cover provision and the state’s power-cover provision have different conditions within their respective scopes.
• Stormwater detention facilities serving residential development: The Town’s technical manual requires perimeter safety fencing when the facility’s high-water level is within 10 feet of a driveway. Otherwise, the fencing decision rests with the owner or developer unless the Stormwater Management Board requires it. The manual’s fenced wet-bottom pond illustration shows an 8-foot fence, while the general residential fence provision sets a 6-foot maximum. Facility fencing therefore needs site-specific review by the Stormwater Management Board and Zoning Administrator.
PRIVATE RESTRICTIONS
Homeowners’ association covenants, private subdivision and deed restrictions, architectural-review covenants, private easements, boundary agreements, agricultural agreements, recorded partition-fence agreements and conservation easements operate independently of public approval. They may impose more restrictive fence locations, materials, heights, design or approval conditions.
These private instruments are distinct from public subdivision requirements, public utility and drainage easements, and regulated-drain rights-of-way. A Town permit does not replace compliance with an applicable private agreement. Dyer’s Section 10-140 recognizes the more restrictive applicable standard where requirements differ.
REVIEW AND ENFORCEMENT CONTEXT
Fence issues are typically reviewed during permit or approval review when required, and through complaint-based code enforcement. Examples include:
• Building and zoning review: Application plans, approved construction, the residential height limit, and decorative front-yard findings.
• Drainage and easement review: Blocked swales, recorded drainage or utility conditions, and Town or County-regulated-drain encroachments.
• Floodplain and pool review: Applicable floodplain development approval and local or state pool access-control conditions.
• Excavation review: Applicable right-of-way excavation requirements and Indiana 811 notice, response and marking obligations.
Section 10-141 provides for written zoning complaints, investigation and appropriate action by the administrative official. The Building Commissioner and Zoning Administrator also administer correction of zoning violations under Section 10-133.
USING THIS INFORMATION
This page provides general orientation on how residential fence rules are structured and applied within the Town of Dyer, Indiana. Updated October 2026.
In addition to local fence rules, certain Indiana laws apply statewide. See Statewide Fence Laws in Indiana.
It is not legal advice and does not replace official ordinances, permits, certificates, improvement-location approvals, development approvals, applicable building-code requirements, surveys, or professional guidance. Rules and interpretations may change, and application may vary based on zoning district, plan-commission jurisdiction, county zoning coverage, site conditions, subdivision/land-development status, easements, rights-of-way, floodplain or floodway status, stream conditions, stormwater or drainage requirements, regulated-drain conditions, road or highway conditions, INDOT jurisdiction, historic/design/special-district status, rural or agricultural context, livestock, lawful-fence or agricultural partition-fence context, live-fence or spite-fence conditions, local permit administration, pool-barrier use, Indiana 811 utility-excavation requirements, and private restrictions such as HOA covenants, deed restrictions, private agreements, recorded partition-fence agreements, or conservation easements. Before purchasing materials or beginning construction, confirm current requirements and site-specific limitations with the Dyer Building Department and Zoning Administrator and any applicable private agreements. If this page conflicts with official ordinances, published guidance, adopted district guidelines, or direction from the responsible Dyer official or Lake County Surveyor and Drainage Board for County-regulated drains, the official sources control. For legal advice or legal interpretation, consult a licensed attorney.