FENCE RULES – CHESTERTON (TOWN), INDIANA

OVERVIEW

This page covers residential fence work within the incorporated boundaries of the Town of Chesterton, in Porter County, Indiana. Chesterton administers its own municipal zoning and fence-permit requirements.

Chesterton combines a local fence-permit process with height rules tied to public rights-of-way, building planes and alleys. Fences beside a public right-of-way other than an alley are limited to 4½ feet. The six-foot residential rule has separate restrictions involving both the owner’s and adjoining property’s front building planes and proximity to an alley. Applications require a survey-plat sketch, an easement agreement and a stake inspection before construction. Wood, metal, plastic and masonry appear in the fence definition, while vinyl/PVC and chain-link are not specifically named in the ordinary rule. Easements, corner visibility, planned developments, floodplain conditions and pool-barrier use can change the answer. Updated November 2026.

Quick questionChesterton answer
Permit or approvalChesterton administers a Fence Permit Application through the Building Department. The application requires a survey-plat sketch, applicable contractor estimate/drawing, signed fence-easement agreement and a preconstruction stake inspection. The published fence fee is $80; ordinary permits expire after 180 days. Additional site approvals can apply.
Typical fence heightMaximum 4½ feet adjacent to public rights-of-way other than alleys. Six feet is the stated height in residential, residential-business and business zones: section 806B says fences and hedges “may be six feet in height.” A six-foot fence cannot be in the front building plane of the owner’s or adjoining property, or within five feet of an alley right-of-way in a residential zone.
Placement & property linesSection 806 does not specify a universal numeric setback from a private property line. The survey plan must show distances to all property lines. The six-foot alley restriction, easements, rights-of-way, visibility and public development conditions are separate limits.
Common fence materialsWood: named in the ordinance’s fence definition. Vinyl/PVC: not specifically named; the definition uses the broader term plastic. Chain-link: not specifically named; the definition uses the broader term metal.
Important local conditionsFence rules may be further affected by street and alley frontage, the adjoining property’s building plane, corner visibility, public or recorded easements, planned-development and plat conditions, floodplain or floodway status, a qualifying regulated drain, public-ground excavation, pool-barrier use and private restrictions.
Official local resourceTown of Chesterton Fence Permit Application

The table above is for quick reference; additional fence-rule details appear in the corresponding sections below. Before purchasing materials or beginning construction, read the sections that apply to the property, review the linked official sources, and confirm site-specific questions with the Chesterton Building Department or the responsible office identified for the issue.

GOVERNANCE

The Chesterton Town Council is the municipal rule-adopting authority. The principal zoning source is the Chesterton Town Code, including Appendix A, the Unified Comprehensive Zoning and Subdivision Control Ordinance. Appendix A applies to incorporated land within the Town. Section 806 contains the ordinary fence-and-hedge rules; other sections address accessory uses, public obstructions, subdivision easements and planned unit developments.

• Building Department and Building Commissioner: Administer the fence application, building-code requirements, applicable permits, inspections and code enforcement. Ordinance 2025-29 replaces Chapter 5, Article III, concerning building permits and fees. The current fence-specific application supplies the survey, easement and stake-inspection requirements for that permit category.

• Advisory Plan Commission, Town Council and Board of Zoning Appeals: The Advisory Plan Commission makes recommendations on zoning text, zoning maps and planned unit developments (PUDs), and has decision-making responsibilities for subdivision plats and site plans. The Town Council adopts zoning and planned-development ordinances. The Board of Zoning Appeals handles its authorized variance and appeal functions.

• Engineering and stormwater: The Town Engineering Department performs floodplain administration, subdivision and infrastructure review, and related mapping and drainage work. The Town’s Storm Water Management Board and municipal separate storm sewer system administration handle applicable stormwater and erosion-control requirements.

• Public roads and regulated drains: The Street Department and Street Commissioner administer Town public-ground excavation and right-of-way requirements with Engineering. The Indiana Department of Transportation, or INDOT, administers state-highway right-of-way work. The Porter County Surveyor and the responsible county drainage or stormwater body have distinct functions for legally qualifying regulated drains; a municipal drain’s statutory status and any transfer of jurisdiction matter.

• Indiana building-code framework: The currently effective residential code is the 2020 Indiana Residential Code, 675 IAC 14-4.4, adopting the 2018 International Residential Code with Indiana amendments. Indiana replaced model Section R105 with an additions-and-alterations section. There is no Indiana statewide seven-foot fence permit exemption from model R105. Local fence permits, land-use conditions and special approvals remain governed by their applicable sources.

• Qualifying agricultural partition fences: IC 32-26-9 applies only when at least one of the adjoining parcels is agricultural land: land zoned or otherwise designated agricultural, used for crops or livestock, or reserved for conservation. Section 2’s boundary-fence duty concerns an owner whose property is outside, abuts or is adjacent to a town or city’s corporate boundary. The agricultural partition-fence provisions below apply only within that statutory context. The township trustee has the chapter’s specified default and watercourse-dispute responsibilities; these duties are separate from Chesterton’s ordinary fence permit and zoning rules.

PERMIT AND APPROVAL REQUIREMENTS

• Fence application: Chesterton’s current Fence Permit Application is submitted to the Building Department. It requests applicant and homeowner information, the property’s legal description or parcel number, contractor information, estimated cost of materials and labor, and fence height. A contractor performing the work must be registered with the Town.

• Required fence documents: Submit a copy of the survey plat with the proposed fence drawn on it. Show the distance to all property lines and the dimensions and height of each fence section. Include the contractor’s estimate/drawing if applicable and the signed fence-easement agreement attached to the application.

• Inspection before construction: A stake inspection is required before construction of a fence. The application asks for inspection scheduling at least 24 hours in advance. Permit holders are responsible for arranging required inspections before work is covered or concealed.

• Published fee and expiration: Ordinance 2025-29, section 5-44, lists $80 for fences. An ordinary permit expires 180 days after issuance. Uncompleted work requires permit renewal before it recommences after expiration; the published renewal fee is 50 percent of the original permit fee. Fees are subject to the current schedule at filing.

• General building-permit provisions: Section 5-42 separately requires a permit before excavation, construction, alteration or repair of a building or structure involving a change of use, additional lot coverage, or a cost exceeding $1,000. Plumbing and electrical work require permits regardless of those conditions. The same article recognizes permit-specific forms, submission criteria and inspection conditions; the current fence form supplies the fence-specific requirements described above.

• Property in a floodplain: The fence application directs an applicant answering yes to its floodplain question to submit the Floodplain Development Permit Application. The Town’s Flood Damage Prevention Ordinance, Ordinance 2022-15, expressly includes erection of walls and fences in development and requires a Floodplain Development Permit before development in a special flood hazard area. This ordinance replaces the older Chapter 9 text.

• Floodplain application information: Section 9-17 requires application to the Floodplain Administrator before work. The applicable submission includes a description of the development, its location relative to roads and streams, the legal description, scaled plans and a site development plan showing existing and proposed locations and grades. Additional information depends on the work, flood zone and watercourse conditions. Floodway state approval, evidence of an applicable exemption, or an engineering assessment can be an additional prerequisite under the specific branches described below.

• Construction within a larger regulated project: Chapter 24 requires the applicable Construction Plan/Storm Water Pollution Prevention Plan and Erosion and Sediment Control Permit for covered disturbance of at least one acre, or smaller disturbance within a larger common plan that will disturb more than one acre. Individual lots within an approved project remain subject to that project’s plan and erosion controls.

• Excavation in a street, alley or public grounds: The Town’s excavation application must be filed at least 48 hours before work. Approval must be obtained before work begins, with a copy signed by the Street Commissioner and Town Engineer before excavation. The application identifies an emergency exception, such as a water-main break. This process applies to public-ground work; it is separate from ordinary fence-permit review.

• State right-of-way work: INDOT requires a below-ground occupancy permit for excavation or grading on state right-of-way. Its Electronic Permit System administers state permits. Town fence approval and a state right-of-way permit are separate approvals.

• Planned developments and site approvals: An adopted planned unit development ordinance, approved plan, plat or written commitment can impose property-specific fence conditions. A variance or other authorized land-use approval follows its own process through the responsible Town body.

• Pool-barrier use: The pool-permit process governs a fence used as a residential pool barrier. Chesterton’s current pool application and the current state residential pool code publish different barrier-height and access-control language. Their specific requirements and the current state-code citation are set out under MATERIAL AND CONSTRUCTION LIMITS.

• Qualifying agricultural partition-fence defaults: In the IC 32-26-9 context described under GOVERNANCE, an interested owner who has built, rebuilt or repaired that owner’s portion first gives the defaulting owner, agent or tenant twenty days’ notice to perform the defaulting owner’s portion. If the default continues for twenty days, the complaining owner notifies the township trustee. The trustee estimates the cost and, within a reasonable time, gives the defaulting owner a statement and notice of probable cost. If the fence remains unbuilt or unrepaired twenty days after receipt of that trustee notice, the trustee must do the work, using only fence materials most commonly used by community farmers. For a fence on a township line, the complaining owner’s township trustee has jurisdiction unless disqualified. A trustee who is related to an interested owner or is an interested owner is replaced as specified by the chapter with the nearest eligible other-township trustee. Trustee construction costs follow the chapter’s certified-statement and county process and are placed on the affected property’s tax duplicate for collection as taxes.

• A qualifying regulated-drain corridor: Written consent from the responsible drainage authority is required before placing a permanent structure in a statutory regulated-drain right-of-way. The actual drain’s legal status, corridor and administering body must be established for the property.

FENCE PLACEMENT RULES

• Private property lines: Section 806 does not specify a universal numeric setback from a private property line for an ordinary residential fence. The permit sketch must show the proposed fence’s distance to every property line. A legal boundary, zoning setback, street right-of-way, recorded easement, drainage feature and approved development line are different constraints. An existing fence, tax-map line, curb, ditch, mowing line or edge of pavement does not establish the legal property boundary.

• Six-foot fences and building planes: In a residential zone, a six-foot fence cannot be constructed in the front building plane of either the owner’s property or the adjoining property. The neighboring property’s building plane is part of the published restriction.

• Six-foot fences beside alleys: A six-foot fence cannot be within five feet of an alley right-of-way in a residential zone. This is the alley condition attached to the six-foot rule. Street-frontage height limits are separately stated below.

• Qualifying agricultural partition-fence lines and owner shares: Within IC 32-26-9’s agricultural and municipal-boundary scope described under GOVERNANCE, section 2 requires the partition fence on the dividing line regardless of when the properties were divided, subject to the chapter’s watercourse provisions. Unless the chapter otherwise provides or the owners have already divided responsibility, a north–south line assigns the north half to the east owner and south half to the west owner; an east–west line assigns the west half to the north owner and east half to the south owner. An owner who built a different half and maintained it for at least five years may continue maintaining that portion. Section 3 allocates building, rebuilding and repair costs proportionately to the rods or proportion of fence each owner owns, whether the ownership is fee simple or a life estate.

• Watercourses affecting a qualifying agricultural partition fence: Under IC 32-26-9-3, if a ditch or creek crosses the division line and adds maintenance expense over the stream, and the owners cannot agree on their proportionate shares, the township trustee appoints three disinterested citizens to apportion the partition fence to be built by each owner. If a ditch or creek forms, covers or marks the dividing line so that the required partition fence cannot be built and maintained on it, each owner must build a separate fence on that owner’s property as near the line as practical and maintain it at that owner’s expense.

• Floodgate decisions for qualifying agricultural partition fences: Where a required partition fence crosses a ditch or creek and a stationary crossing is impracticable, section 3 requires the floodgate or similar structure described under MATERIAL AND CONSTRUCTION LIMITS. If the structure adds expense and the owners disagree on its character or their cost shares, either owner may give the trustee written notice identifying the disagreement. The trustee appoints three disinterested township citizens to determine the structure and apportion its cost, considering the fence portions each owner maintains. A majority determination is final and binding. If an owner fails to construct or pay the determined share within thirty days after the determination, the trustee must construct the structure and recover the defaulting owner’s costs, including the arbitrators’ compensation, through the ordinary partition-fence process. Repair, rebuilding and replacement follow the arbitrators’ determination.

• Thorn hedges beside streets or alleys: Section 806 prohibits maintaining a thorn hedge or similar growth within five feet of a public street or alley right-of-way.

• Sidewalks, streets, alleys and intersections: Town Code section 23-1 prohibits a fence, barricade, gate or structure that obstructs pedestrian passage on sidewalks or crosswalks or vehicle passage on streets or alleys, subject to the section’s exception for properly permitted work under the Building Code or street-excavation ordinance. At intersections, a fence, barricade or structure cannot unreasonably obstruct the vision of approaching motorists or pedestrians as determined by the Town Council.

• Fences in easements—the Town’s two published provisions: Appendix A, section 602C, states that an accessory building or use cannot be located within a dedicated easement or right-of-way. The Town’s current fence application separately requires a signed agreement addressing a fence installed in an easement: if the Town or utility providers need access, the owner is responsible for removal and reinstallation at the owner’s expense. These are different published treatments of easement installations. The easement terms and the Building Department’s site-specific application of these provisions are material to the proposed fence location.

• Public subdivision easements: The subdivision certificate of dedication preserves Town and utility rights to install, maintain and access facilities. It prohibits a permanent building on the easement and allows other use only when it does not interfere with utility use. Section 1000-56 calls for utility/drainage easements at least 12 feet wide, with access to all portions; six feet from each of two adjoining lots can form that width. Rear-lot or between-lot easements are 20 feet wide, formed by ten feet from each adjoining lot. A watercourse requires a stormwater easement or drainage right-of-way sufficient for its purpose. The recorded plat and actual easement determine the affected part of a lot.

• Common swales: Town Standards describe a common swale serving two or more lots or properties as protected by an easement dedicated for maintenance and repair. The swale design standard is a minimum ten-foot width and six-inch depth. On a lot affected by such a swale, the drainage function and dedicated access remain separate from the private property line.

• Planned unit developments: Public PUD ordinances, plans and continuing approval conditions can control fence location and design on affected property. These public development conditions operate separately from private association covenants.

• Special flood hazard areas: A fence in an applicable special flood hazard area falls within the Town’s floodplain-development process. Section 9-8 uses the applicable Federal Emergency Management Agency (FEMA) and Indiana Department of Natural Resources (DNR) flood data, including later updates and best-available data. Where several flood zones or base-flood elevations affect a development, section 9-10 applies the most restrictive zone and highest applicable elevation.

• Riverine regulatory floodways: Section 9-22A.1 requires the application and pertinent plans/specifications to go to the Indiana Department of Natural Resources for approval unless the work qualifies for a general license or statutory/rule exemption. Local action waits for state approval or evidence of qualification for the exemption. The local permit cannot be less restrictive than the state approval or exemption criteria, and more restrictive Town conditions take precedence.

• Floodway hydraulic conditions: In a floodway shown on the Flood Insurance Rate Map, the ordinance’s no-increase requirement applies unless the required Conditional Letter of Map Revision and related requirements are met; a revision cannot authorize an increase affecting a structure. For a DNR-delineated floodway not yet shown as such on the FEMA map, the cumulative development must not adversely affect efficiency or unduly restrict capacity. The ordinance defines that adverse effect as a regulatory-flood elevation increase of at least 0.15 foot, determined by the prescribed hydraulic comparison.

• Riverine fringe and undelineated flood areas: In a riverine fringe, the Town may issue the local permit when the ordinance is satisfied. In a mapped floodplain with no established floodway/fringe, an upstream drainage area greater than one square mile follows the DNR review/assessment branch; an area less than one square mile requires the applicant’s engineering analysis of floodplain limits and one-percent annual-chance flood elevation. Near an unmapped waterway with an upstream drainage area greater than one square mile, the ordinance requires the DNR review/assessment process before local approval.

• Floodplain fill or structures displacing flood storage: Section 9-23J requires at least equal compensating excavation below the regulatory flood elevation—a 1-to-1 replacement ratio—for authorized fill or structure volume below that elevation. Excavation ordinarily occurs in the floodplain and same immediate watershed. Its conditional adjacent-floodplain alternative requires the same immediate property, excavation below the regulatory elevation, floodwater access, no ponding when not inundated and no refilling. Drainage ways cannot be obstructed; grading must allow floodwater access; material must remain stable and protect neighbors from increased runoff. Plans precede site work, and the required certified fill/excavation survey follows site work before construction.

• Qualifying agricultural fences in a floodway: Indiana’s separate state permit exemption applies to an agricultural fence primarily used to keep animals in or out that does not obstruct the flow of water or debris through the floodway. The Town’s local floodplain permit is a separate requirement.

• Larger land-disturbance projects and individual lots: Chapter 24’s one-acre/common-plan requirements depend on the area and development context. An individual lot within a permitted larger project must comply with the approved Storm Water Pollution Prevention Plan and applicable erosion/sediment measures. The Chapter 24 permit threshold turns on disturbed acreage and common-plan status.

• Legally qualifying regulated drains: IC 36-9-27-33 provides a corridor that can extend 75 feet at right angles from a tiled drain’s centerline or the top edge of each bank of an open drain, as determined by the surveyor. Permanent structures need written drainage-board consent; temporary structures must be removed immediately when ordered. Trees, shrubs and woody vegetation also require written consent. For covered new regulated drains and urban drains, authorized reductions cannot be less than 25 feet from each open bank or 15 feet from a tiled centerline. A further tiled-drain reduction in a platted subdivision cannot be less than seven feet on each side or less than the surveyor’s recommendation. These reductions require the prescribed authority’s action.

• Municipal drains and transfers: Under IC 36-9-27-21, a drain partly or wholly within a municipality is subject to that chapter only if the municipality constructed it under the chapter or the specified predecessor drainage statutes. Sections 20 and 20.6 allow accepted transfers of jurisdiction and the associated entry/right-of-way powers. The responsible body and corridor therefore depend on the actual drain, rather than every ditch or swale having the statutory 75-foot corridor.

• Indiana 811 before post-hole excavation: Before covered fence-post digging, submit a locate notice through Indiana 811 at least two full working days, but no more than ten calendar days, before work. A working day runs from 7 a.m. to 6 p.m. Indianapolis time, excluding Saturdays, Sundays and state/national legal holidays. The normal lawful start is no earlier than 7 a.m. on the next working day after two full working days have elapsed following receipt of notice. The statutory earlier-start exception requires all affected operators’ electronic positive responses showing facilities marked or no affected facilities. Check the responses and site markings, and affirmatively acknowledge receipt of the required operator information through Indiana 811, in its prescribed manner, before starting. A notice expires at 11:59 p.m. Indianapolis time twenty days after its receipt date. Incomplete work needs a new request/notice and new affected-operator markings before it continues. The narrow exception is excavation solely with hand tools, on property owned or controlled by the excavator, no more than twelve inches deep. Follow the statutory tolerance-zone and equipment restrictions, and notify 811 of evidence of unmarked facilities or illegible markings. Utility notice is separate from permits, easements, property boundaries and other approvals.

FENCE HEIGHT AND VISIBILITY RULES

• Adjacent to public rights-of-way other than alleys: Section 806A limits fences, hedges and similar structures or growths to 4½ feet.

• Residential, residential-business and business zones: Section 806B states that fences, hedges and similar structures or growths “may be six feet in height.” Six feet is the stated height for these zones; the subsection uses that permissive wording. It then prohibits a six-foot fence in the front building plane of the owner’s or adjoining property, or within five feet of an alley right-of-way in a residential zone. Those are the published six-foot location restrictions; the separate 4½-foot limit applies adjacent to other public rights-of-way.

• Corner lots: The Chesterton Town Standards, Part B(5)(c), prohibit a fence, wall, hedge or shrub planting that obstructs stopping sight distance on a corner lot at the intersection of two streets. Town Code section 23-1 separately addresses unreasonable obstruction of motorists’ and pedestrians’ intersection vision.

• Subdivision sight-triangle table: Appendix A, section 1000-53K, publishes through-street/stop-street sight-triangle legs of 500/30 feet for arterial and collector streets; 250/25 feet for local and cul-de-sac streets; and 50/20 feet for alleys. These are the table’s street-design classifications and paired measurements.

• Town Standards’ separate sight-distance reference: Part B(2)(k) and B(4) instead direct sight triangles and minimum stopping sight distance to the latest INDOT Design Manual. The subdivision table’s fixed measurements and the separately published Town Standards’ INDOT reference are different published approaches. The Town Engineering Department’s site-specific application is needed for a layout affected by these provisions.

• INDOT stopping-sight design reference: The referenced manual’s Chapter 42, Figure 42-1A, lists rounded passenger-car stopping distances of 80, 115, 155, 200, 250, 305, 360, 425, 495, 570, 645 and 730 feet for design speeds of 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65 and 70 mph, respectively. Section 42-1.02 uses a 3.5-foot driver-eye height and two-foot object height. These measurements belong to the applicable roadway sight design.

• INDOT intersection and driveway geometry: Chapter 46 varies intersection sight design with traffic control, design speed, vehicle and geometry. Its passenger-car intersection check uses a 3.5-foot eye and object height. The stop-controlled-road eye location is 18 feet behind the travel-lane edge for a new/reconstruction project or 14.5 feet for a resurfacing, restoration or rehabilitation (3R) project. For a low-volume drive, its check may use an eye about ten feet from the travel-lane edge. The particular roadway condition determines the applicable geometry.

• Qualifying boundary hedges or live fences: IC 32-26-5-1 requires a hedge or live fence along the dividing line between properties owned by different persons to be cut and trimmed at least once each calendar year to no more than five feet high and three feet wide. Under section 2, a signed written complaint by an adjoining landowner alleging neglected trimming requires the township trustee to examine the live fence within five days. If it has not been trimmed, the trustee gives written notice requiring trimming and removal of the brush to the owner’s property within thirty days after receipt. Notice is read to the owner or left at the usual residence; a nonresident township owner receives it by mail to the last known post-office address. If the owner, agent or tenant does not comply, the trustee must arrange the trimming and brush removal immediately after the thirty days and recover the expenses by suit in the county circuit or superior court. Chesterton’s separate street-frontage and thorn-hedge restrictions also apply in their stated locations.

• Lawful qualifying agricultural partition-fence construction: In the IC 32-26-9 context described under GOVERNANCE, section 3(f) recognizes a straight board-and-wire, straight wire, straight board or picket fence four feet high; a straight rail fence 4½ feet high; or a worm rail fence five feet high. Each must be sufficiently tight and strong to hold cattle, hogs, horses, mules and sheep. These are the chapter’s lawful-partition-fence specifications for qualifying properties; Chesterton’s ordinary zoning and frontage rules remain separate.

• Spite-fence nuisance: IC 32-26-10-1 treats a fence-like structure unnecessarily exceeding six feet and maliciously erected or maintained to annoy adjoining owners or occupants as a nuisance. Both the unnecessary height and malicious-purpose elements are part of that statute.

MATERIAL AND CONSTRUCTION LIMITS

• Ordinary fence definition: Appendix A defines a fence as a structure other than a building, designed and constructed of wood, metal, plastic or masonry, used as a barrier to enclose property, mark a boundary or provide protection.

• Wood: Wood is expressly named in the definition. Height, frontage, building-plane, visibility, permit and applicable site conditions still govern a wood fence.

• Vinyl/PVC: The ordinary fence provision does not specifically name vinyl or PVC. The definition uses the broader category plastic.

• Chain-link: The ordinary fence provision does not specifically name chain-link. The definition uses the broader category metal.

• Barbed or electrified wire beside public streets or alleys: Section 806D prohibits constructing or maintaining a fence or similar structure composed in whole or in part of barbed wire or electrified wire along any public street or alley within the Town.

• Workmanship and maintenance: Chapter 5 requires construction, alteration and repair of buildings and other structures to be performed in a good and workmanlike manner according to accepted trade standards. Ordinance 2023-02 requires accessory structures and their appurtenances to remain in good repair and sound structural condition.

• Residential pools—the current state rule’s scope: Under 675 IAC 14-4.4-38, R326.2.16, the residential-pool definition includes an in-ground or on-ground pool capable of water deeper than 42 inches, and all pools inside a residence regardless of depth, intended for noncommercial use by no more than two owner families and their guests. Artificial lakes are excluded. R326’s residential pool provisions are enforced by local units.

• Residential pools—state access-control alternatives: R326.27.3 provides four alternatives: (1) walls or fencing at least four feet high completely surrounding the pool and deck, except for self-closing and latching gates and doors capable of being locked; (2) other means at least four feet high, deemed impenetrable by the enforcing authority at construction, completely surrounding the pool and deck when the pool is unused; (3) a combination of the first two methods completely surrounding the pool and deck, with the stated gate and door conditions; or (4) a qualifying power safety pool cover. The self-closing, latching and lockable gate/door conditions apply to the first three methods.

• Residential pools—complete state power-cover conditions: The power safety cover must provide a continuous connection between cover and deck that prohibits access when fully closed. Mechanical operation must prevent opening or retraction without a key, a key-and-switch, or a touch pad with a personal access code. The necessary tracks, rollers, rails, guides and other accessories must be installed in accordance with the manufacturer’s instructions to achieve those access and operation requirements. An identification tag must state compliance with ASTM F 1346-91 (2018) for power safety pool covers.

• Chesterton pool application’s different barrier language: The Town’s April 22, 2026 Pool Permit Application calls for a minimum five-foot barrier surrounding the pool: a fenced yard or pool fence with a locking gate if the pool is less than five feet above grade. It requires gates to have self-closing and self-latching devices at the top of the gate, and accepts self-latching retractable stairs as a substitute for closing gates. Item 8 describes an in-ground pool power safety cover meeting ASTM F1346 with a carrying capacity of at least 485 pounds, in lieu of a fence.

• Pool form and current state code: The Town form’s five-foot language differs from the current state rule’s four-foot access-control alternatives. The form also cites 675 IAC 20-4, which the Indiana Department of Homeland Security lists as repealed April 24, 2011, with residential pools moved to the residential code. The current state provision is 675 IAC 14-4.4-38, R326. The Town form and state rule therefore publish different barrier/cover treatments. Confirm the applicable barrier or cover arrangement with the Chesterton Building Department before a pool-barrier fence is designed or purchased.

• Floodgates in qualifying agricultural partition fences: In the IC 32-26-9 context described under GOVERNANCE, a required partition-fence crossing where a stationary fence is impracticable must instead use floodgates or similar structures sufficiently high, tight and strong to turn hogs, sheep, cattle, mules, horses or other domestic animals. They must swing up during high water and connect continuously with the partition fences. The chapter’s watercourse allocation, disagreement and construction process is described under FENCE PLACEMENT RULES. Floodplain, floodway and regulated-drain approvals remain separate requirements where applicable.

• Chicken enclosures: Town Code section 4-13 requires chickens to be completely and securely enclosed, under the owner’s control and on the owner’s property. Chickens and coops are confined to the rear yard. The coop must provide at least ten square feet per chicken, protect against rodents, wild birds and predators, and be at least ten feet from the property line. Those dimensions govern the coop; ordinary perimeter fences remain subject to the separate fence rules.

PRIVATE RESTRICTIONS

HOA covenants, private subdivision restrictions, deed restrictions, architectural-review covenants, recorded private easements, boundary agreements, conservation easements and other private instruments operate independently from Chesterton’s public fence rules and may be more restrictive. Appendix A preserves existing easements, covenants and agreements between parties.

Under IC 32-26-3-1, adjoining owners choosing to erect, repair, maintain or pay for a separating fence differently from Article 26 must use a written agreement signed by the adjoining owners and record it with the recorder in the county or counties where the properties lie. A Town permit does not resolve ownership or replace a required private approval or agreement.

REVIEW AND ENFORCEMENT CONTEXT

Fence issues are typically reviewed during permit or approval review when required, and through complaint-based code enforcement. Examples include:

• Fence permit and stake inspection: The Building Department reviews the fence location, survey-plat distances, section dimensions/heights, applicable contractor documents and easement agreement, and requires the stake inspection before construction.

• Height and frontage: Review can involve the 4½-foot public-right-of-way limit, the stated six-foot height in residential, residential-business and business zones, either property’s front building plane, the five-foot alley condition for six-foot fences, or a property-specific public approval.

• Sight and public passage: Fences and gates can be reviewed for blocked sidewalks, crosswalks, streets or alleys, unreasonable intersection-vision obstruction, and the applicable subdivision/Town Standards sight design.

• Easement, plat and PUD conditions: Review can address public utility or drainage access, a recorded public easement, the fence-easement agreement’s removal/reinstallation obligation, and an adopted planned-development or site-plan condition.

• Floodplain and drainage: The Floodplain Administrator reviews applicable fences as development in special flood hazard areas. DNR approval or exemption evidence, mapped/undelineated floodway conditions, compensating flood-storage work, erosion controls, or a qualifying regulated-drain corridor can require separate review.

• Pool-barrier use: Pool permit review involves the Town form’s five-foot barrier/cover language and the current state R326 access-control requirements. These are pool-use conditions, distinct from ordinary yard-fence heights.

• Public-ground excavation: The Street Commissioner and Town Engineer review permitted street, alley and public-ground excavation; INDOT administers state right-of-way work within its jurisdiction.

• Maintenance and animal enclosure: Unsafe or deteriorated accessory structures, public-street/alley barbed or electrified wire, thorn-hedge placement, insecure chicken enclosures and animals running at large can raise the relevant Town code issues.

• Qualifying boundary live fences: The township trustee administers IC 32-26-5’s complaint, examination, notice, trimming and expense-recovery process for qualifying boundary hedges and live fences. The annual dimensions and procedural deadlines are described under FENCE HEIGHT AND VISIBILITY RULES.

• Qualifying agricultural partition fences: The township trustee has the statutory default, cost-recovery and watercourse-dispute functions described above, subject to IC 32-26-9’s agricultural and geographic scope. These processes are separate from Town fence-permit review.

• Spite-fence and private matters: A fence-like structure unnecessarily over six feet and maliciously intended to annoy an adjoining owner or occupant falls within Indiana’s spite-fence nuisance framework. HOA, deed, boundary and private agreement issues remain separate from Town permit approval.

• Utility excavation: Indiana 811 notice, operator responses/markings, affirmative acknowledgment and valid-ticket requirements apply to covered fence-post excavation independently of Town approval.

USING THIS INFORMATION

This page provides general orientation on how residential fence rules are structured and applied within the Town of Chesterton, Indiana. Updated November 2026.

In addition to local fence rules, certain Indiana laws apply statewide. See Statewide Fence Laws in Indiana.

It is not legal advice and does not replace official ordinances, permits, certificates, improvement-location approvals, development approvals, applicable building-code requirements, surveys, or professional guidance. Rules and interpretations may change, and application may vary based on zoning district, plan-commission jurisdiction, county zoning coverage, site conditions, subdivision/land-development status, easements, rights-of-way, floodplain or floodway status, stream conditions, stormwater or drainage requirements, regulated-drain conditions, road or highway conditions, INDOT jurisdiction, historic/design/special-district status, rural or agricultural context, livestock, lawful-fence or agricultural partition-fence context, live-fence or spite-fence conditions, local permit administration, pool-barrier use, Indiana 811 utility-excavation requirements, and private restrictions such as HOA covenants, deed restrictions, private agreements, recorded partition-fence agreements, or conservation easements. Before purchasing materials or beginning construction, confirm current requirements and site-specific limitations with the Chesterton Building Department and any applicable private agreements. If this page conflicts with official ordinances, published guidance, adopted district guidelines, or direction from the Chesterton Building Department or the responsible public office identified for the issue, the official sources control. For legal advice or legal interpretation, consult a licensed attorney.