FENCE RULES – O’FALLON (CITY), MISSOURI
OVERVIEW
This page covers residential fences inside the incorporated City of O’Fallon, Missouri, in St. Charles County. A city mailing address alone does not place property within the city’s regulatory territory. Unincorporated St. Charles County and O’Fallon, Illinois, are outside this guide.
O’Fallon requires a fence permit for fences and decorative posts at least thirty inches high. Its ordinary maximum is six feet six inches, with front-setback restrictions and a limited street-side-yard allowance on lots adjoining more than one public street. Wood, vinyl/PVC and residential chain-link are recognized materials, but construction, finish and maintenance rules still apply. Corner visibility has separate zoning and curb-based nuisance restrictions. Pools, retaining walls, easements, drainage, floodplain development, grading and certain designated historic features can change the work or approvals required. Updated November 2026.
| Quick question | O’Fallon answer |
|---|---|
| Permit or approval | A fence permit is required before constructing fences or decorative posts at least 30 inches high. The minimum fence fee is $25; separate approvals and limited exceptions apply. |
| Typical fence height | Ordinary maximum: 6 feet 6 inches, including accompanying structures and decorative posts. Greater height needs an applicable exception; pool and retaining-wall safeguards remain separate. |
| Placement & property lines | Side and rear property lines may be used subject to the applicable restrictions. Fencing forward of the required setback line is generally prohibited; multi-street lots have a limited street-side-yard allowance. Easements, drainage and visibility still control. |
| Common fence materials | Wood: expressly recognized. Vinyl/PVC: expressly recognized, subject to minimum quality standards. Chain-link: allowed in residential and industrial zoning, prohibited in commercial zoning; pool specifications also apply. |
| Important local conditions | Fence rules may be further affected by street corners, pools, retaining walls, easements, drainage, grading, floodplain development, designated historic features, approved development plans, animal enclosures and existing sewage lagoons. |
| Official local resource | O’Fallon Building and Code Enforcement permit resources |
The table summarizes ordinary fence rules. The following sections explain their conditions, exceptions and the separate requirements that apply to particular properties and uses.
GOVERNANCE
O’Fallon is a constitutional home-rule city with a Mayor–City Administrator–City Council government. The City Council adopts municipal ordinances. The city’s zoning rules apply within its municipal boundaries, alongside the locally adopted 2021 International Residential Code, International Property Maintenance Code and International Swimming Pool and Spa Code, each with local amendments. The residential code’s permit exemptions operate within that code; they do not remove separate zoning approvals.
The Administrative Officer, designated by the Director of Planning and Development, administers the fence standards. Building and Code Enforcement handles construction permits and code administration; Engineering handles grading, drainage and the specified excavation approvals. The Plan Reviewer is the Floodplain Administrator. The Historic Preservation Commission has the specific designated-property role described below. Separate fire districts are independent governments. For private sewage systems, city law expressly requires state and St. Charles County compliance, county permits and inspection; that delegation does not transfer county zoning generally into the city.
PERMIT AND APPROVAL REQUIREMENTS
• Fence permit and application: Section 400.273’s fence standards require the property owner or authorized agent to obtain a permit from the Administrative Officer before construction of a fence or decorative post 30 inches or more high. The permit becomes valid after a completed application is approved and all applicable fees are paid. The current fee ordinance sets a minimum $25 fence fee. The city’s fence application guidance calls for two plot plans showing the fence, gates and decorative posts. City approval does not constitute subdivision approval.
• Timing and compliance: Construction must start within six months of permit issuance and finish within one year, or the permit expires. Renewal is subject to Administrative Officer review. A new fence that violates the fence standards must be dismantled and removed at the owner’s expense. Section 500.390 also prohibits starting regulated fence or property-alteration work without proper permits.
• Separate construction-code exemption: The locally adopted residential code exempts fences not over 7 feet from permits under that code. That exemption does not waive the separate 30-inch zoning fence-permit threshold or increase the ordinary six-foot-six height limit. The applicable construction code depends on the building and use; a residential-code exemption is not automatically an exemption for work governed by the separate building code.
• Limited fence-permit exceptions: Temporary protective fencing securing an area during active excavation, construction or grading does not need the fence permit. Fencing installed as a structural component or safety device, including fencing on a retaining wall, also has a fence-permit exception, but must be shown as an improvement and reviewed and approved by the Administrative Officer. Other applicable construction, pool and site safeguards remain.
• Existing fences and replacement: A fence in place before the fence section’s effective date is treated as legal nonconforming fencing. It may remain while it is not replaced or relocated and its frame or structural supports are not altered to extend, enlarge or intensify the nonconformity. Alteration requires compliance with the current fence standards. Maintenance and repair are exempt from that nonconformity provision. Before work, have the Administrative Officer determine whether the proposed repair also needs a fence or construction permit.
• Retaining-wall approvals: Section 405.275 requires a retaining-wall permit for walls over 48 inches, measured from the top of the base to the top of the wall, or walls supporting a surcharge or altering channelized drainage. Engineering approval and permitting are required for drainage-altering walls regardless of height. Engineered work needs signed and sealed wall plans and calculations plus a site plan submitted to Building and Code Enforcement. As-built plans by a licensed engineer are required when Engineering requires them.
• Retaining-wall code exemption: The residential code separately exempts retaining walls not over 4 feet measured from the bottom of the footing to the top of the wall, unless they support a surcharge, impound Class I, II or IIIA liquids or alter channelized drainage. This different measurement does not remove Section 405.275’s independent permit triggers.
• Designated historic features: For a designated landmark or part of one, demolition or permanent removal of a significant exterior feature specifically identified as a basis for designation requires a certificate of appropriateness before the city issues a permit. The application includes plans and specifications for Commission review; denial may be appealed to the City Council. Work must start within six months; the certificate lasts 18 months and may be renewed. Other work may proceed without Commission action under Section 120.470, subject to ordinary permits, and Section 120.480 advice is voluntary.
• Mapped floodplain work: A development permit is required before covered construction or other development in a mapped special flood hazard area. The application supplies the relevant plans, elevations and watercourse-change information to the Floodplain Administrator. Floodway encroachments require a registered professional engineer’s or architect’s certification that the work will not increase base-flood levels. Applicable flood-resistant construction, drainage and anchorage requirements depend on the work and substantial-improvement triggers.
• Clearing and grading: Section 405.070 requires a clearing permit for any lot. Even chainsaw-only clearing that leaves roots undisturbed requires minimum erosion controls. Grading and grubbing controls must precede work; stabilization, temporary controls and a stormwater pollution prevention plan apply where required. The code separately requires grading-plan review before moving 50 cubic yards or more; that plan threshold is not a general exemption for smaller grading. A building-permit applicant signs the city’s acknowledgment of approved grading and drainage compliance.
• Road and utility excavation approvals: A right-of-way work permit under Section 406.020 is separate from other permits. For emergency work, notice and application are due as soon as practicable, no later than the third business day. Excavation in the specified hazardous-pipeline or utility easement requires an Engineering permit requested at least 3 and no more than 10 working days before excavation. Section 406.110 also requires notification-center notice and at least 48 hours for marking; the state working-day requirements below apply as well. State-highway right-of-way work requires the applicable state permission.
• Downtown and approved development plans: In the mapped Downtown Overlay, existing-use provisions and the underlying setbacks apply, subject to any individually approved site-plan setback reduction. Its design guidelines are optional; their standards apply when that option is chosen. Existing approved site plans, buffers and easements can govern a property. The general Commission site-plan requirement excludes single-family homes, mobile homes and multifamily buildings with four or fewer units; an ordinary backyard fence does not automatically require a professionally engineered development plan.
FENCE PLACEMENT RULES
• Property lines and easements: Fences and decorative posts must be on or within the owner’s property lines. Side- and rear-property-line placement is allowed subject to the fence section’s restrictions. A permit does not establish the boundary. A fence in an easement is subject to removal by the property owner or another authorized party without compensation. A state permit is required for placement in state right-of-way.
• Front and street-side yards: Fencing forward of the required lot setback line is prohibited. On a lot where more than one side abuts a public street, the fence may project up to 10 feet over the building line only in the street-adjacent side yard. Fencing within the front-yard setback remains prohibited. This allowance is measured over the building line, not as a ten-foot distance from the street.
• Decorative posts and street access: Ornamental posts or stakes with attached chains, rope or similar material serving only aesthetic purposes may be in the front yard when less than 30 inches high and at least 2 feet from the property line. That exception concerns decorative posts, not a general front-yard fence allowance. Every fence must provide a gate or opening at least 3 feet wide on any side adjacent to a street.
• Drainage and maintenance access: Fence installation may not obstruct manholes or inlet covers or impede or disturb existing swales, drainage patterns or natural flows on the property or adjacent property. Public stormwater infrastructure must remain accessible. Fences may be allowed where city maintenance access is preserved; an obstruction in an easement or right-of-way must be moved at the owner’s expense when access is needed. Owners maintain their creeks, ditches, surface flows and driveway drainage pipes.
• Retaining-wall locations: Front-yard retaining walls may be no more than 4 feet high and must be at least 10 feet from the front property line or outside the utility easement, whichever is greater; the Planning and Zoning Commission or Board of Adjustment may vary that requirement. Side- and rear-yard walls must be at least 2 feet from the property line; those over 48 inches may not occupy public utility easements. Public-right-of-way placement needs the City Engineer’s written approval. The owner bears removal or reconstruction costs if an allowed easement wall must be moved for the easement’s use.
• Hazardous-liquid pipelines: For a federally regulated hazardous-liquid pipeline with an inside diameter of at least 8 inches, the restricted area extends 25 feet to either side; the limited-improvement area extends 25–50 feet. Section 400.250 expressly permits fences in the limited-improvement area. Structures and excavation in the restricted area are prohibited unless an applicable listed exception applies or the Building Official determines the work will not disturb the pipeline or impede its operation or maintenance. Engineering’s separate excavation permit remains applicable.
• Excavation notice: For excavation covered by Missouri Section 319.026, notice to the notification center is generally due at least 2 and no more than 10 working days before work. Working days exclude Saturdays, Sundays and legally declared state or federal holidays. The notice supplies the required excavator and responsible-person contact details, start date, planned depth and type of work, trenchless or explosives use if applicable, and a detailed site/location description and access directions. White lining may clarify an area that cannot be identified from its location description. If an owner cannot determine the area from the notice, the excavator must clarify it with white flags or paint, project plans or an onsite meeting. The center process does not locate all private owner lines or excluded facilities, and does not replace a boundary survey or permission to dig.
• Utility responses and early work: Facility owners normally mark or communicate a no-conflict response within 2 working days after the notification day, measured from midnight, unless an extended start is agreed through the center. Earlier excavation requires confirmation that all affected facilities have been located. A no-facilities response may use the supplied telephone numbers or recording device, email, a site marking of clear or OK, an in-person response or the locate-status system. If the supplied telephone numbers are the only contact method, two attempts satisfy that contact provision. For notified trenchless work, the owner supplies depth information to the best of its knowledge or ability from its records. Either side may request an onsite marking-clarification meeting within two working days, or agree to initial marking there.
• Missing utility response: If an owner does not respond, the excavator must notify the center again before excavation. The owner then has 2 hours to mark or contact the excavator. A response requiring marking must meet the same-working-day deadline for notice received by 2 p.m., or 10 a.m. the next working day for later notice. Excavation may begin under this provision only if the owner fails to mark or contact as required; reasonable care still applies. A lack of paint by itself is not immediate clearance.
• Ticket life, markings and emergencies: A notice expires at 11:59 p.m., 21 consecutive calendar days from the work start date. Preserve visible marks. If work has not begun within 10 working days as described in the request, request relocation before starting. If markings become unusable, request remarking through the center in the same manner as the original notice; the owner has the original response time to remark. Only the facility owner or its representative makes facility marks. An excavator may owe reasonable remarking costs for failing to preserve marks with reasonable care or making repeated unnecessary requests despite usable marks. Before work, the excavator must determine best practices for confirming horizontal and vertical locations under site conditions; hand or soft digging is used when possible. Careful, prudent excavation remains required. For unexpected emergencies presenting clear imminent danger, excavation may proceed with reasonable precautions and notice as soon as practical. The notified owner must mark or contact the excavator within two hours, supply immediately available information and state when marking will occur if it cannot mark within that time.
• Utility damage and public roads: Damage, dislocation or disturbance of a facility or protective devices, including trace wires, encasements, cathode protection and permanent aboveground stakes, must be reported to the notification center. Damage or contact with a pipeline resulting in a release of hazardous liquid or gas requires an immediate 911 call. The excavator may not conceal the damage or attempt repairs without the facility owner’s authorization. For sewer lines or facilities, emergency temporary repairs may be made after notification without owner/operator authorization to prevent further damage; the reporting obligation remains. An incorrectly located or unmarked facility also requires notice to the center, and the owner must contact the excavator or correctly locate it within 2 hours. Separate Missouri Department of Transportation permission applies to excavation in a state highway or its right-of-way under Section 319.025, subject to the railroad-right-of-way exception.
• Survey evidence: Section 60.355 prohibits knowingly moving, removing, defacing or destroying the specified survey monuments, markers and boundary evidence, subject to its registered-land-surveyor exception. It includes restoration liability and the stated surveying-cost and attorney-fee remedy. Utility marks identify facilities; they do not establish land ownership.
• Shared-fence removal and neighbors: Missouri’s partition-fence systems govern their own livestock, contribution, repair and removal circumstances, rather than requiring every residential neighbor to pay half. Under Section 537.350, an owner removing a covered division fence adjoining cultivated fields must give the adjoining owner six months’ written notice; Section 272.110 separately permits entry onto adjoining land to repair the owner’s part of a division fence. Under Section 272.120, removal requires all owners’ consent except to open a public road or highway; the local-option Section 272.320 also has a repair exception. These consent provisions belong to their respective partition-fence systems and are separate from the written-notice duty. Permit approval decides neither system nor private ownership or contribution rights.
FENCE HEIGHT AND VISIBILITY RULES
• Ordinary maximum and taller exceptions: The ordinary maximum is 6 feet 6 inches for fencing, accompanying structures and decorative posts. A greater height may be approved through a conditional use permit under Article VII only if it causes no further obstruction to vision at streets, driveways, sidewalks or other traffic areas and adequate planting screens the outside attractively. Planning and Development receives the application for the applicable Commission and Council review. No conditional use permit is needed for greater height required to comply with a current city ordinance.
• Zoning visibility triangles: Section 400.273 prohibits fences or decorative posts in a designated 25-foot sight triangle or otherwise impeding vehicular vision. Separately, Section 400.260(F) applies at public-street access points and street intersections: within the triangle formed by the right-of-way lines and a line joining points 25 feet from their intersection, development must not materially impede vision between 36 inches and 15 feet above the grades at the backs of the intersecting-street curbs. Equivalent private-street points or the approved site-plan triangle also apply.
• Additional street-corner restriction: Section 220.105’s separate nuisance restriction addresses a lot alongside intersecting streets or where a street enters or runs into another. It prohibits a fence, sign, signboard or billboard nearer than 25 feet to the curb of such street or greater than 2 feet above the street crown at the intersection. This curb-and-crown restriction is separate from the right-of-way triangle and designated-triangle provisions. The Administrative Officer administers the fence-location review where a corner design engages these separate measures.
• Retaining-wall height and guards: A retaining wall may exceed 4 feet if designed and engineered by a licensed engineer, but may not exceed 6 feet without a fence or guard on top. A wall more than 30 inches high supporting a walking surface within 2 feet requires a guard built under the applicable building or residential code. Front-yard height remains subject to its separate four-foot limit and variance route. The fence-height rule does not supply an averaging method or an automatic increase for a fence placed on a wall.
• Pool construction and permanent barrier height: For in-ground pool and spa construction, a fence at least 4 feet high must surround the site from the first excavation until the permanent barrier is complete. The permanent barrier is at least 48 inches above outside grade around its entire perimeter and for a horizontal distance of 3 feet outside it. Ground clearance on the outside is at most 2 inches over nonsolid surfaces such as grass or gravel, or 4 inches over solid surfaces. A barrier mounted on an above-grade pool or spa has no more than a 4-inch gap between the structure top and barrier bottom.
MATERIAL AND CONSTRUCTION LIMITS
• Wood: Natural and treated wood are expressly recognized by the fence standards. Height, placement, finish, upkeep and any applicable pool-barrier design still apply.
• Vinyl/PVC: PVC and other synthetic materials are expressly recognized and must meet the section’s minimum quality standards for residential as well as commercial applications. Before choosing a product, have the Administrative Officer review its specifications against the section’s minimum quality standards and identify which of the separately listed commercial-bufferyard construction specifications apply to the proposed fence.
• Chain-link: Chain-link is permitted in residential and industrial zoning and prohibited in commercially zoned areas. Pool enclosures have the smaller opening limits below.
• Other materials and finished face: The recognized, nonexclusive list also includes brick, stone and other masonry, wrought iron and decorative aluminum. The finished side faces outward, with visible supports and structural components inward. Materials must be contiguous and use the same material and design across the property unless the Administrative Officer approves a different material or design.
• Restricted and prohibited fencing: Barbed wire, razor wire, hardware cloth, wire mesh and electrified fencing are prohibited, among other prohibited materials. The barbed-wire exception is for industrial-security fences at least 5 feet 6 inches high with an approved conditional use permit; wire must be vertical or tilted inward. An invisible electronic animal-containment system may be used only as a maintained secondary restraint in addition to a visible primary enclosure. That animal-control provision does not authorize exposed electrified fencing.
• Maintenance: Owners must repair, paint, remove or otherwise attend to unsightly or unsafe fencing. An Administrative Officer compliance notice normally allows 15 days; a longer period may be allowed for undue hardship. The property-maintenance code requires fences, walls and retaining walls to remain structurally sound and in good repair. Exterior surfaces must remain in good condition without mold or algae; wood other than decay-resistant wood needs protective treatment. Peeling or chipping finishes must be removed and surfaces repainted; corrosion must be treated, except on surfaces designed to stabilize by oxidation.
• Retaining-wall construction and drainage: Terraced retaining walls must be separated as recommended by a geotechnical engineer or by a minimum ratio of 2 feet horizontal for each 1 foot of wall height. A permitted wall needs a drainage plan routing water around or away from it, contained onsite or discharged to a city-approved location. Stormwater may not flow over the wall. Drainage alteration needs prior Engineering approval regardless of wall height.
• Pool-code scope and cover exception: O’Fallon applies its adopted swimming pool and spa code with local amendments. A lockable ASTM F1346 safety cover on a spa or hot tub provides the stated exemption from Sections 305.2–305.7. The city’s amendment does not extend that perimeter-barrier exception to a powered swimming-pool cover. A listed cover may still serve the separate house-wall protection alternative described below. Local law deletes the model’s separate mesh-fence provisions; the ordinary prohibited-material rules still apply.
• Pool openings and horizontal members: Barrier openings must not pass a 4-inch-diameter sphere. Solid barriers may not have handholds or footholds except normal construction tolerances and tooled masonry joints. When horizontal-member tops are less than 45 inches apart, horizontal members belong on the pool side and vertical spaces and decorative cutouts are at most 1¾ inches; the city exempts fences at least 54 inches high from this closely spaced-member subsection only. When horizontal-member tops are 45 inches or more apart, vertical openings are at most 4 inches and decorative cutouts at most 1¾ inches.
• Pool chain-link, diagonal members and clear zone: Chain-link openings are at most 1¾ inches; slats used to achieve that opening must be fastened at top and bottom. Diagonal-member openings are at most 1¾ inches, and the diagonal angle is at most 45 degrees from vertical. Equipment, including pumps, heaters and filters on the same lot but outside the barrier, must be at least 36 inches from its outside.
• Pool gates: Barrier doors and gates must accommodate a lock. Pedestrian gates open outward, away from the pool or spa, self-close and self-latch. Utility or service gates remain locked when unused. Double or multiple gates have at least one leaf secured in place and the adjacent leaf secured with a self-latching device.
• Pool latch mechanisms: For residential pools and spas, an outside-accessed latch release that is not self-locking must be at least 54 inches above finished floor or ground. With a self-locking key, electronic opener or integral combination lock, the lock control and release are no higher than 54 inches above that surface. At a private pool where the only self-latching release is on the pool side, it must be at least 3 inches below the gate top. Openings in the door, gate and barrier within 18 inches of an inside release may not exceed ½ inch in any dimension.
• House walls as pool barriers: Where a dwelling or structure wall provides direct pool or spa access through doors, gates or windows, it needs the applicable protection: a UL 2017 water-hazard entrance alarm on doors, gates and operable windows with sills less than 48 inches above the indoor finished floor; a listed and labeled ASTM F1346 safety cover; or approved equally protective measures such as self-closing, self-latching doors. Alarm-deactivation controls in ordinary dwellings are at least 54 inches above the finished floor; in required Accessible, Type A or Type B dwellings they are 48–54 inches above it.
• Onground pool walls and ladders: An onground pool wall may serve as the barrier when its bottom is on grade, its top is at least 48 inches above grade around the entire pool, it meets the applicable barrier rules and the manufacturer permits that use. A wall-mounted barrier must also reach at least 48 inches above grade around the entire pool, with both wall and barrier complying. Access ladders or steps must be capable of being secured, locked or removed unless surrounded by a compliant barrier. Openings resulting from that securing, locking or removal must reject a 4-inch sphere; mounted barriers follow the manufacturer’s installation instructions.
• Natural pool barriers: A pool or spa adjoining a natural waterbody may omit the barrier along that shoreline only when public shoreline access is not permitted or allowed and the remaining barriers extend at least 18 inches beyond the water’s edge. Natural topography that prevents direct access may substitute only with governing-body approval and protection at least equivalent to Sections 305.2–305.5.
• Existing-pool maintenance safeguards: The property-maintenance code separately requires private pools, spas and hot tubs more than 24 inches deep to have a barrier at least 48 inches high measured from the outside. Gates self-close and self-latch. If the latch is less than 54 inches from the bottom of the gate, its release is on the pool side. The gate must close and latch positively when released 6 inches from the gatepost. Replacement or changes may not reduce an existing barrier’s effectiveness. The ASTM F1346 spa/hot-tub cover exception remains. The bottom-of-gate reference differs from the new-work latch rule’s floor/ground reference.
• Declared dangerous animals: A declared dangerous animal must be kept indoors or in a locked, child- and escape-resistant pen at least 5 by 10 feet, with secure sides and top, weather protection and an attached floor or sides embedded at least 12 inches. Only one dangerous animal may occupy the structure, except a female with offspring younger than 3 months. The structure must satisfy zoning/building rules; warning signs must be visible from the entry roadway and on the pen or fenced yard. Ordinary animal-control and no-running-at-large duties remain separate from these dangerous-animal dimensions.
• Vehicle-storage enclosures: Section 217.030’s exception for specified inoperable or unlicensed vehicles requires a completely enclosed locked building or a locked fenced area not visible from adjacent public or private property. Its separate licensed-business exception has its own conditions. The enclosure does not waive other vehicle-storage or nuisance requirements.
• Existing sewage lagoons: For an existing sewage lagoon, St. Charles County administers the applicable local system requirements under the city’s delegation. The county prohibits new lagoons. Its existing-system review route determines the requirements for work affecting an existing lagoon or enclosure; a state lagoon-fence specification does not authorize a new lagoon in O’Fallon.
• Conditional state sewage-system scope: Section 701.031’s state-program exclusion applies to an owner’s single-family residence on at least 3 acres, or an owner’s residential lot of at least 10 acres with no single-family-residence onsite sewage system within 360 feet of any other onsite sewage system and no more than one single-family residence per 10 acres in the aggregate. It excludes the specified lots adjacent to lakes operated by the Corps of Engineers or a public utility. Every system point must be more than 10 feet from adjoining property lines, with no effluent trespass, surface- or groundwater contamination or scientifically determined nuisance. Separate local requirements still apply.
• Conditional state lagoon fence: Where the state lagoon-fence rule applies, the fence must be complete before dwelling occupancy and at least 4 feet high, with no bottom gaps. Welded, woven or chain-link wire must be no smaller than 14 gauge; cattle/hog panels may substitute with tee-post line posts. Posts must be pressure-treated wood or galvanized/painted steel, driven, tamped or concrete-set; line-post spacing may not exceed 10 feet and corner posts must be properly braced. Location may be no closer to the operating water edge than the berm center, measured at the 3-foot operating water level. The gate must be properly hinged, 4 feet high, of comparable materials and effectively latched.
• Lagoon recommendations: The state rule recommends, rather than mandates, line-post depth of 18 inches, corner-post depth of 24 inches, a fence setback no greater than 30 feet from the water edge and gate width of 36–48 inches. These recommendations do not displace the mandatory construction duties or the county’s local requirements.
• Licensed-home outdoor play areas: At a licensed family childcare home, the outdoor play area must be on or adjoining the premises and accessible without hazards. A fence is required where necessary to protect against traffic, water or other hazards. For homes initially licensed after the rule’s effective date, and for new fences at existing homes, the fence must be at least 42 inches high. All fences must prevent children from crawling or falling through or becoming entrapped.
• Licensed-home pools and animals: At those licensed family childcare homes, swimming and wading pools must be fenced against children’s access. For homes initially licensed after the rule’s effective date, the pool fence must be at least 42 inches high with a locked gate. Aboveground pools may use a 42-inch fence around the pool top with barricaded deck steps. Hazardous animals must be absent or securely penned where children cannot reach them. These licensed-home provisions operate alongside the city’s separate pool and animal rules.
• Livestock at large: Missouri Section 270.010 prohibits owners from permitting its listed horses, mules, asses, cattle, swine, sheep and goats to run at large. A person may restrain them, and the specified police officer must do so. A known owner receives written notice within 3 days. The notice states the claimed feeding/keeping compensation and damages. The owner owes reasonable taking-up, keeping and feeding compensation and actual damages caused. For an accident on a public road or highway, the owner is not responsible if the animals were outside the enclosure through no fault or negligence of the owner. If the owner is unknown, or taking-up, keeping and feeding compensation remains unpaid, the statutory stray process applies. Unpaid damages alone do not define that route.
PRIVATE RESTRICTIONS
Recorded subdivision covenants, homeowners-association architectural requirements, private easements and enforceable boundary, maintenance or cost agreements may impose additional obligations. Their terms and applicable Missouri law determine their effect. City approval does not constitute subdivision approval or waive recorded rights.
A fence permit does not convey ownership, locate the boundary, settle shared costs or authorize interference with an easement. The age or position of a fence alone does not settle title, and providing a gate does not automatically satisfy another person’s access rights. Public partition-fence duties remain separate from private agreements.
REVIEW AND ENFORCEMENT CONTEXT
Fence issues are typically reviewed during permit or approval review when required, and through complaint-based code enforcement. Examples include:
• Permit and site review: Permit thresholds, applications, expiration, replacement classification, retaining-wall engineering, designated historic features, floodplain work and grading.
• Placement and visibility: Front and street-side yards, the distinct corner restrictions, street access, drainage, easements and pipeline areas.
• Construction and upkeep: Finished faces, prohibited fencing, deterioration, pool barriers and gates, retaining-wall guards and conditional animal, vehicle or lagoon enclosures.
• Separate private matters: Boundary, ownership, covenant, access and shared-cost disputes remain distinct from municipal permit and code enforcement.
USING THIS INFORMATION
This page provides general orientation on how residential fence rules are structured and applied within the City of O’Fallon, Missouri. Updated November 2026.
In addition to local fence rules, certain Missouri laws apply statewide. See Statewide Fence Laws in Missouri.
It is not legal advice and does not replace official statutes, ordinances, orders, permits, certificates, development approvals, applicable building-code requirements, surveys, recorded documents or professional guidance. Rules and interpretations may change, and application may vary with the identified municipality, including its actual municipal or county class, charter, adopted program or special district, and each function’s verified territory, the authority responsible for each issue, current code requirements and amendments, zoning and site conditions, subdivision or plat conditions, easements, rights-of-way, drainage and floodplain requirements, historic or design districts, pool use, agricultural or livestock conditions, fence ownership and shared-fence duties, excavation requirements, and private restrictions subject to Missouri law. Applicable requirements depend on the property’s actual facts and the respective authority of the identified offices. Private agreements and recorded rights remain separate from government approvals. If this page conflicts with controlling law, adopted regulations or official requirements, the controlling authorities govern.