FENCE RULES – COMMERCE (CITY), GEORGIA
OVERVIEW
This page applies to residential fence projects inside the City of Commerce, Georgia. City rules govern within municipal limits. For property in unincorporated Jackson County, see Jackson County fence rules.
Commerce limits fences to four feet in front yards and in any yard abutting a public street. Away from public streets, the height may increase to six feet eight inches at the dwelling’s front building line. Wood and vinyl are expressly allowed, while chain-link has location and construction restrictions. A fence requiring an engineered foundation needs a building permit. Property-line placement also depends on rights-of-way, utility access and visibility. Downtown guidance, highway-corridor frontage, pools, residential sports courts and environmental conditions can change the ordinary answer. Updated October 2026.
| Quick question | Commerce answer |
|---|---|
| Permit or approval | A fence or wall requiring an engineered foundation needs a permit from the Building Official before erection. Right-of-way encroachment and applicable pool, design, floodplain or land-disturbance work have separate approval requirements. |
| Typical fence height | 4 feet in front yards and any yard abutting a public street; up to 6 feet 8 inches from the front building line where the yard does not abut a public street. Special uses and downtown guidance have additional standards. |
| Placement & property lines | Fences and walls are excluded from building/accessory-structure setbacks, and city guidance allows side/rear property-line placement. No separate numeric side/rear fence setback is published. Legal boundaries, rights-of-way, easements, utility access, visibility and protected areas remain relevant. |
| Common fence materials | Wood: expressly allowed; downtown guidance limits designs and locations. Vinyl/PVC: vinyl expressly allowed; PVC is not separately named. Chain-link: restricted to permitted yard locations, with coating and insert rules; downtown guidance is more restrictive. |
| Important local conditions | Fence rules may be further affected by public-street or highway frontage, downtown design guidance, driveway sight areas, pools, residential sports courts, agricultural zoning, animal enclosures, recorded easements, floodplain development, stream buffers and subdivision conditions. |
| Official local resource | City of Commerce Planning & Development |
The table above is for quick reference. The corresponding sections below explain the requirements in more detail. Before purchasing materials or beginning construction, read the sections that apply to the property, review the linked official sources, and confirm site-specific questions with City of Commerce Planning & Development or the office responsible for that issue.
GOVERNANCE
The Commerce City Council adopts local development regulations. The City’s Unified Development Code contains the principal fence standards in Section 3-036. The Zoning Administrator, through Planning & Development, administers and interprets the UDC. The Building Official and Building Inspector administer applicable construction permits and inspections; City Code Enforcement addresses ordinance violations.
Fence requirements also appear in the retained January 2001 subdivision regulations and amendments, downtown design guidance, environmental provisions and pool materials. The Zoning Administrator administers floodplain requirements. The Public Works Director or designee approves required stormwater plans. Commerce is a local issuing authority for erosion and sediment control. Public Utilities includes Public Works, Water, Electric, Gas, Stormwater, Sewer and Wastewater divisions.
For state-road access and encroachments, the responsible authority is the Georgia Department of Transportation (GDOT). The UDC also identifies Jackson County Environmental Health in the pool-approval process. City Code Enforcement works with Jackson County Animal Control, while city ordinances continue to apply within Commerce.
Georgia’s current construction-code cycle includes the 2024 International Residential Code, International Building Code and International Swimming Pool and Spa Code, with 2026 Georgia amendments, effective January 1, 2026. These codes operate alongside local zoning and permit administration. The Georgia Department of Community Affairs current-code page provides the applicable editions and amendments.
PERMIT AND APPROVAL REQUIREMENTS
• Engineered-foundation fence or wall: A fence or wall that requires an engineered foundation under the building code must have a permit approved and issued by the Building Official before erection. Section 3-036 does not publish a general height-based building-permit threshold for ordinary fences.
• Public right-of-way: A fence or wall may not encroach into public right-of-way without Zoning Administrator approval. The City publishes a ROW Encroachment Permit Application. Its fence guidance requires a recorded plat when installation is proposed near or on the right-of-way.
• Subdivision or project entrance: Fences and walls forming an entrance monument require plans prepared by a registered landscape architect and approval by the Zoning Administrator.
• Retaining-wall permit documents: The City’s retaining-wall application requires engineer certification for all retaining-wall permits. It requests the wall’s total length, highest point above grade, project information and certified design. The construction requirements are described under MATERIAL AND CONSTRUCTION LIMITS.
• Downtown changes and design review: The City’s Downtown Design Guidelines page directs owners to obtain approval before making changes. The handbook describes its project area as generally bounded by Short, Clayton, Piedmont, Madison, Spring, Victoria and Homer streets. The UDC’s design-review area includes the Central Business District (CBD) and Office, Commercial and Residential (OCR) lots within 500 feet of a CBD boundary. Highway Corridor architectural review is separately administered under the UDC.
• Design-review exemptions and submissions: The UDC exempts ordinary maintenance or repair without a material change in design, material or appearance; additions of accessory structures to detached single-family dwellings; and other minor changes accepted by the Zoning Administrator. Where a design-review permit is required, the owner or agent submits at least a site plan and elevation drawings. Photographs and material/color samples may also be required.
• Pool projects: Permanent above-ground and in-ground pools require a permit before work begins. The City requires a site plan showing the pool and property-line setbacks, an electrical permit application and applicable erosion-control documentation. Pool houses and other associated structures have separate permit applications. The UDC identifies necessary Building Official and Jackson County Environmental Health approvals. A City Inspector’s approved final inspection, including fencing, is required before pool occupancy.
• Flood-area site work: Fence-related excavation, grading, fill or other regulated development in a flood-hazard area requires prior approval under the flood-damage-prevention provisions. Applications go to the Zoning Administrator and include scaled plans showing the proposed work, dimensions, elevations, materials and drainage facilities, as applicable.
• Erosion and land disturbance: The UDC exempts fences and related minor land-disturbing activities that result in minor soil erosion from its erosion-control article. Nonexempt clearing, grading or excavation is subject to the applicable land-disturbance process. The separate exemption for projects under one acre does not apply to a larger common plan of at least one acre or work within 200 feet of the bank of state waters, subject to its stated exclusions for certain rain-fed drainageways and non-year-round streams. Sediment must still be kept on the property in the specified drainageway circumstances.
• Stormwater plans: Where a stormwater plan is required for covered site development, approval by the Public Works Director or designee precedes the relevant development, land-disturbance or building approval. Exemptions include individual single-family/duplex lots outside a subdivision or phased development with less than one acre disturbed, and additions or modifications to existing single-family/duplex structures.
• Cemeteries and burial grounds: Work that knowingly disturbs a cemetery, burial ground, human remains or burial objects for development or a change of use requires a City Council permit. The UDC separately exempts minimally invasive investigation techniques such as remote sensing and metal probes.
• Variances and appeals: City Council may grant a variance upon the required findings. An application includes the City form and fee, notarized owner signature, legal description, survey plat, site plan, letter of intent, required disclosure and written explanation of the variance criteria. Administrative variances are discretionary, limited to a 20% modification to each standard, and require Zoning Administrator and City Manager review. A denied administrative variance may proceed to the Council variance process. Administrative decisions or interpretations may also be appealed to City Council under Article 14.
FENCE PLACEMENT RULES
• Side and rear property lines: Fences and walls are not subject to building or accessory-structure setbacks. City fence guidance allows placement on a side or rear property line. Commerce does not publish a separate numeric side/rear property-line setback for an ordinary fence. This placement rule does not establish where the legal boundary lies.
• Road and property boundaries: A public right-of-way, recorded easement and zoning setback are different from the private property line. Existing fences, utility poles, curbs, pavement edges, ditches and tax-map lines do not establish a legal boundary. The City requires a recorded plat for fence/wall installations proposed near or on the right-of-way.
• Utility access and yard gates: All fences and walls must allow utility-meter access at all times. An enclosure restricting access from front to rear yards must include a gate positioned parallel to the front lot line between the side lot line and principal structure. If the enclosure begins forward of the building line, a gate must be positioned parallel to the front lot line. The gate must be at least three feet wide. City utility agents also have published access rights for meter and utility-service work.
• Recorded subdivision easements: Final plats may establish utility, drainage and pedestrian easements. Under UDC Section 15-207, a drainage easement is required along a manmade drainage channel or pipe outside street right-of-way. The minimum drainage, water or sanitary-sewer easement width is 20 feet, or 30 feet for a combined easement; required pedestrian easements are at least 10 feet. These dimensions describe subdivision easements, whose location and terms must be checked on the property’s recorded documents.
• Retained subdivision easement provisions: The January 2001 regulations authorize specified side/rear utility easements up to 20 feet wide and require drainage easements or drainage right-of-way along watercourses crossing a subdivision. Recorded drainage routes and maintenance access can affect an existing lot’s fence layout.
• Required zoning buffers and landscape strips: Required zoning buffers must remain undisturbed except for allowed planting and authorized encroachment or grading. A retaining wall, or a fence/wall authorized by the Zoning Administrator for screening or aesthetic effect, may be located in a required frontage landscape strip. The applicable buffer and landscape conditions remain part of the approved development.
• Highway Corridor residential frontage: Within the Highway Corridor Overlay District, a residential use or residentially zoned lot abutting a collector or arterial street must have frontage on a local street and a 20-foot no-access easement along the collector/arterial frontage. Along that frontage, excluding required sight triangles, Section 4-207 requires one of three treatments: a solid brick/stone masonry wall at least four feet high, erected before a building permit; an iron-picket fence at least four feet high with brick/stone pillars every 50 feet; or a Zoning Administrator-approved strip of canopy trees and shrubs impenetrable by vehicles.
• Highway Corridor coverage: The UDC describes the overlay along U.S. highways and streets where the City borders Jackson County, as reflected on the official zoning map. Its boundary extends 500 feet from the highway centerline, or the centerline of the nearest direction of travel on a divided highway. A partially included parcel is subject to the overlay as a whole, including after subdivision. The UDC states an exception for development, improvements, structures, plans or permits approved before the division’s adoption, unless otherwise specified.
• New subdivisions on arterial-road curves: New subdivisions abutting an arterial road posted above 30 mph at a specified horizontal or vertical curve must install uniform fencing and/or walls along the entire arterial property line. Guardrails are also required in the applicable curve. The Zoning Administrator may require an additional buffer up to 25 feet wide where arterial right-of-way is less than 60 feet.
• State-highway access: For access to U.S. or state highways, GDOT requirements apply when more restrictive than City standards. Required GDOT permits must be provided before the applicable City development/building approval. State limited-access fence conditions are described under MATERIAL AND CONSTRUCTION LIMITS.
• Floodways: Within a regulatory floodway, encroachments associated with the project require hydrologic and hydraulic analysis and a registered professional engineer’s supporting data/certification demonstrating no increase in flood levels or floodway widths during the base flood.
• Flood areas without complete flood data: For an A-zone stream without usable base-flood/floodway data, Section 11-308 restricts encroachment within the greater of the stream’s width or 20 feet measured from the top of bank, unless professional-engineer certification demonstrates no more than a one-foot flood-level increase. In an AE area with base-flood elevations but no designated floodway, Section 11-309 requires certification that the cumulative development will not raise the base-flood water surface more than one foot. These are conditional flood-development requirements.
• North Oconee River corridor: The protected corridor extends 100 feet horizontally from each riverbank and requires a natural vegetative buffer. Existing uses have the stated exemption, but expansion of their land or building area is not exempt. Work affecting this corridor must comply with its separate permitted-use and buffer requirements.
• Water-supply watershed conditions: The UDC’s large-watershed reservoir-tributary branch applies to perennial stream corridors outside a seven-mile radius of the reservoir boundary; its small-watershed branch separately covers qualifying perennial streams. Where these provisions apply, the stream corridors have a 50-foot buffer and 75-foot impervious-surface setback, measured from stream banks. Existing-use, utility, forestry and agricultural exceptions have their own conditions. In a small watershed, single-family detached development has a 25% impervious-cover limit; recorded subdivision lots carry individual allocations. Approved water-quality/low-impact measures may increase the standard limit to no more than 125% of that limit, and approved pervious paving is excluded. These provisions apply to covered land disturbance and impervious work associated with a project.
• State-water buffers and nonexempt disturbance: For work subject to the erosion-control article, Section 8-202(o) establishes a 50-foot buffer measured horizontally from the point where normal flow or wave action has wrested vegetation. Its stated exceptions include approved variances, qualifying drainage structures and ephemeral streams. Buffers remain naturally vegetated during covered construction. The stated owner-occupied single-family thinning/trimming provision requires protective vegetation and stream shading to remain. The minor-soil-erosion fence exemption and other applicable buffer programs must each be considered for the proposed work.
• Wetlands: In protected wetlands, development must comply with the UDC’s restricted-use, grading, fill and structure provisions. Required land-disturbance, development, building and subdivision plans must identify protected wetlands and include the prescribed wetland statement. State and federal wetland requirements also apply where triggered.
• Downtown fence locations: Downtown residential design guidance places flat wood-board privacy fences only around rear yards, with the front sections no closer to the front façade than approximately halfway between the front and rear façades. It calls for preservation of original fences and retaining walls. The detailed height and material guidance appears below.
• Georgia 811 before post-hole digging: Before mechanized fence-post excavation, contact Georgia 811 as required by Georgia’s underground-facility law. Georgia 811 recommends its free locate service even for manual digging. Its digging process calls for a ticket at least three business days before digging. The statutory appropriate-notice framework is two to eight business days. Except where a statutory exception applies, excavation under a locate request may not take place more than 30 calendar days after its effective date. If the work will not be completed within that period, submit an additional locate request with appropriate notice before continuing beyond it. Additional notices may not expand the tract or parcel covered by the existing request. Wait for the applicable effective date/response period and check utility responses, markings and any signs of an unmarked utility before beginning or continuing under the renewed request. Elapsed time alone is not clearance to dig.
FENCE HEIGHT AND VISIBILITY RULES
• Front yards and public-street frontage: Section 3-036(c) limits fencing to four feet in a front yard and in any yard abutting a public street. This includes a public-street side or rear yard.
• Side/rear height away from a public street: The fence remains at or below four feet until it is parallel to the principal structure’s front building line. At that point it may increase to six feet eight inches, provided the yard does not abut a public street.
• Multiple-frontage lots: The front-yard definition includes frontage along a public street, private street or access easement. On a double-frontage lot with an established no-access easement along one frontage, the adjoining yard is not considered a front yard under that definition. The separate four-foot limit for any yard abutting a public street continues to apply.
• M-1 and M-2 districts: Where the M-1 or M-2 zoning provisions apply, fence height may increase to eight feet with Zoning Administrator approval.
• Residential sports courts: A sports court on an individual residential lot must be in the rear yard, at least 15 feet from side and rear property lines, and enclosed by a fence or freestanding wall at least eight feet high under Section 3-074.
• Residential driveway sight triangle: Structures and landscaping must not exceed three feet within a triangle measured 20 feet along the driveway edge and 20 feet along the street right-of-way line. Signposts and other structures under eight inches in diameter have the stated exception. Section 6-503(j) controls this residential-driveway clearance.
• Intersection and driveway sight distance: Section 6-313 measures sight distance from the centerline of the entering road or driveway, 10 feet back from the nearest trafficway edge. It uses an eye height of 3.75 feet and a target six inches high in the center of each approaching lane. The full sight line must remain clear of obstructions. Design speed is the posted speed limit.
• Published sight-distance values: Table 6-3-4 lists the following speed/distance pairs, in feet each way: 25 mph—125; 30—125; 35—150; 40—185; 45—230; 50—475; 55—350; 60—450; 65—550. Its footnote limits 125-foot street spacing to internal residential streets and states a 150-foot minimum for external nonresidential street spacing. Section 6-313(b) permits design in accordance with AASHTO’s Geometric Design of Highways and Streets where its standards conflict with the section.
• Landscaping subject to the landscaping division: Where that division applies, no shrub/tree between 2½ and 12 feet high may be within 20 feet of intersecting street/road/highway/railroad right-of-way lines or a street right-of-way’s intersection with either driveway edge. Single-family/two-family dwellings are exempt from the division unless landscaping is required as a project-approval condition; accessory dwelling units and the stated agricultural/minor-work categories also have exemptions.
• Downtown residential pickets and privacy fencing: The downtown handbook recommends painted/stained wood pickets no taller than 42 inches, with gaps of 1½ to 3½ inches. Flat wood-board fences may be up to six feet only in the specified rear-yard locations. These downtown design guidelines accompany the general City fence standards.
• Pool barriers: The local pool enclosure minimum is four feet. The state pool-barrier standard requires at least 48 inches above grade on the side facing away from the pool, continuously around the barrier and for three feet horizontally outside it. Additional openings, gate and construction requirements appear below.
• Retaining-wall height: For a retaining wall visible from public right-of-way, the Zoning Administrator may limit height during development/grading-plan approval. Section 3-036 does not specify a separate formula for measuring a fence above a retaining wall.
MATERIAL AND CONSTRUCTION LIMITS
• Allowed residential materials: Section 3-036(a) expressly allows wood, stone, chain-link, vinyl and composite materials in residential areas, subject to the applicable yard, district and design requirements.
• Wood and vinyl/PVC: Wood and vinyl are expressly listed. PVC is not separately named. Downtown guidance gives additional wood-fence design and location standards. The ordinance also contains the prohibited-material list below.
• Prohibited materials: Fences and walls may not be made of plywood, particleboard, paper, plastic, plastic tarp, tires, pallets, garage doors, canvas, glass block, bottles, bamboo, recycled or discarded materials, or other cast-off, secondhand or unintended fence/wall construction or maintenance items.
• Wire and agricultural districts: Hog wire, barbed wire, poultry netting and razor wire are prohibited in residential zoning districts. Those materials and roll-type fencing are permitted only in AR and AF zoning districts. The UDC does not separately state an ordinary residential electric-fence standard.
• Residential chain-link locations: Non-vinyl-coated chain-link is permitted in rear and side yards only when it does not extend beyond the dwelling’s front building line. All chain-link is prohibited in the front yard or forward of that line.
• Chain-link screening and inserts: Netting or mesh may be installed for screening. Chain-link fences with plastic, vinyl or metal slats/inserts are prohibited in residential zoning districts. Chain-link around a stormwater-management pond must be vinyl coated, including the UDC’s any-district pond provision.
• Finished side and maintenance: The finished side must face outward from the property. Fences/walls must be maintained, repaired when damaged, and replaced or reconstructed when severely damaged or destroyed.
• Yard gates: The required front-to-rear access gate must be at least three feet wide. Cattle gates are prohibited in residential zoning districts.
• Retaining-wall design: For a publicly visible retaining wall 100 feet or longer, the Zoning Administrator may require changes in plane, height, material or texture, or significant landscape massing. The permit’s engineer certification specifies safety factors of 1.5 sliding, 2.0 bearing, 2.0 overturning and 1.5 global stability, plus 1.5 geogrid pullout and rupture where applicable. The certified design must provide drainage and stability, avoid disturbance/erosion of other property, and not block, cross or eliminate access to an easement, buffer, setback, detention/retention pond or tree-save area.
• Entrance-monument articulation: During entrance-monument approval, the Zoning Administrator may require columns/pillars projecting at least six inches horizontally, reaching at least fence/wall height, every 50 feet; or plane projections/recesses at least one foot deep and three feet to less than 20 feet long. Section 3-036(j) states an articulation exception for a fence or wall constructed of brick, masonry, or metal fencing that consists of at least 50% open voids.
• Temporary construction fencing: Section 3-036 does not apply to qualifying temporary construction fencing, including silt fencing, tree-protection fencing and fencing ordered by the Building Official or Zoning Administrator. It must be removed after construction is complete.
• Required tree-protection fencing: Where tree-protection fencing is required for covered land development, it must be at least four feet high and use chain-link, orange laminated plastic supported by posts, wood post-and-rail or an equivalent barrier. It remains until land development is complete; encroachment into the protected area is prohibited.
• Nonexempt residential/infill erosion work: For covered disturbed areas, the UDC requires two perimeter silt-fence rows 36 inches apart, with the intervening area stabilized. Approved Type A, Type C or Type C Alternative may be used on single-residential/infill lots; state-water, sensitive and low-elevation areas require Type C and prohibit Type C Alternative/C-Pop. Different barrier types overlap at least 18 inches in a continuous run.
• Stormwater facilities: Where a stormwater plan is required, its facility details include a 20-foot minimum access easement, gravel access drive, fencing with a locked gate and landscape screening. Residential-subdivision detention facilities are placed on separate HOA-owned lots with continuing maintenance responsibilities.
• Solar panels on fences: Solar energy systems may not be mounted on a freestanding wall or fence.
• Downtown residential design: The downtown handbook calls for compatible, traditional landscape features and preservation of original fences and retaining walls. It recommends iron fences only at pre-1900 buildings; painted/stained pickets at buildings of any period; and rear-yard board fences in the locations and dimensions stated above.
• Downtown chain-link and walls: The handbook advises against chain-link. Where retaining an existing rear-yard chain-link fence is necessary, it calls for dark green or black paint to camouflage it. It advises against freestanding walls and new retaining walls of railroad timber or concrete block.
• Downtown pool and equipment screening: The handbook calls for appropriate fencing to screen a swimming pool from street view. Solar panels are placed on rear façades or in rear yards with plant/fence camouflage, out of street view where possible.
Pool and spa barriers. The following construction standards apply when the fence or enclosure serves as a regulated pool/spa barrier. Commerce’s pool agreement requires a permanent full-perimeter enclosure with non-climbable fencing and locking gates; state construction-code requirements also apply.
• State pool-cover provisions: The ISPSC provides a barrier exception for a spa/hot tub with an ASTM F1346 lockable safety cover, or a swimming pool with an ASTM F1346 powered safety cover. Commerce separately publishes its local pool-enclosure requirement. For a pool/spa without the qualifying cover, Georgia’s amendment requires the permanent compliant barrier to be complete before filling and operation.
• Pool bottom gaps and openings: Maximum gap below the barrier is two inches over nonsolid grade such as grass/gravel, or four inches over a solid surface, measured outside. A pool-top-mounted barrier may have at most four inches between pool top and barrier bottom. Openings may not pass a four-inch-diameter sphere. Solid surfaces must not form handholds/footholds, except normal construction tolerances and tooled masonry joints.
• Pool barrier horizontal and vertical members: If horizontal-member tops are less than 45 inches apart, place those members on the pool side and limit vertical gaps and decorative cutouts to 1¾ inches. At 45 inches or more between horizontal-member tops, vertical gaps may be at most four inches, with decorative cutouts still limited to 1¾ inches.
• Pool chain-link and diagonal members: Chain-link barrier openings are limited to 1¾ inches. Commerce’s residential insert prohibition remains applicable. Diagonal-member openings are limited to 1¾ inches, and the diagonal angle may not exceed 45 degrees from vertical.
• Pool screen enclosures: A qualifying screen enclosure may provide part/all of the barrier under Section 305.2 and must be designed by a registered design professional. Its barrier mesh requires tensile strength at least 100 pounds per square foot under ASTM D5034 and ball-burst strength at least 150 pounds per square foot under ASTM D3787. Such enclosure walls are not dwelling walls.
• Pool mesh fences: Mesh fences other than chain-link follow manufacturer instructions and ASTM F2286, with complying gates. They may not be installed atop an onground residential pool. The inside of the mesh fence must be at least 20 inches from the nearest water edge.
• Pool equipment clearance: Equipment outside the pool barrier, including pumps, filters and heaters, must be at least 36 inches from the barrier’s outside.
• Pool gates and latches: Pedestrian gates must open away from the pool, self-close, self-latch and accommodate a lock. Gates may not swing over stairs. Utility/service gates remain locked when unused. Multiple-leaf gates have at least one leaf secured and the adjacent leaf self-latching. Under Georgia’s amended Section 305.3.3, externally accessed non-self-locking residential latch releases must be at least 54 inches above the finished floor or ground. Where an inside latch is used, openings within 18 inches of it may not exceed ½ inch in any dimension.
• Dwelling or structure wall as pool barrier: Direct-access doors, gates and qualifying windows require the protection specified in Section 305.4: a listed UL 2017 water-hazard entrance alarm, a listed/labeled ASTM F1346 safety cover, or approved equivalent protection such as self-closing/self-latching doors. The alarm window branch covers operable windows with sills below 48 inches above the indoor finished floor. Alarm-deactivation controls in dwellings not required to be accessible/Type A/Type B are at least 54 inches high; in those accessible dwellings, and in structures other than dwellings, controls are 48–54 inches high.
• Onground pool wall as barrier: A qualifying manufacturer-approved pool wall, or wall plus top-mounted barrier, must provide at least 48 inches around the perimeter and meet the applicable barrier construction requirements. Access ladders/steps must be secured, locked or removed, or separately enclosed by a complying barrier. Securing/removing them must not leave an opening passing a four-inch sphere. Top-mounted barriers follow manufacturer instructions.
• Natural pool barriers: At a lake/other natural water edge with no public shoreline access, the barrier may terminate as allowed by Section 305.6 when it extends at least 18 inches beyond the water’s edge. A natural topographic barrier requires governing-body approval and protection equivalent to the applicable barrier standards.
• Ordinary dog confinement: The City requires animals to remain restrained and prevents unattended escape from the owner’s property. A physical dog enclosure must prevent climbing, digging, jumping or other escape; the City defines adequate dog-enclosure space as at least 150 square feet per dog. A permitted invisible-containment alternative requires a sign stating that the system is present.
• Vicious dogs kept outdoors: The City requires a second perimeter/area fence and a separate secure pen or kennel within it, with no shared fencing. The pen has secure sides and top; sides are buried two feet or sunk into concrete. Its gate opens inward and remains locked except while tending the animal. On the owner’s property outside the enclosure, the dog is attended and leashed with a leash no longer than 10 feet, at least 15 feet inside the property boundary unless that boundary is securely fenced.
• Dangerous-animal enclosure: The required proper enclosure prevents entry by young children and escape by the animal, has secure sides, dig-resistant bottoms buried two feet or sunk into concrete, suitable shelter, and an inward-opening gate locked except when tending the animal. The premises require the prescribed visible warning sign, including a symbol warning of danger.
• Backyard chickens where permitted: The residential chicken provision allows no more than six hens and requires confinement by structure/fence rather than free range. The covered enclosure is in the rear yard, provides at least two square feet per chicken, complies with residential setbacks, is at least 25 feet from a residential structure and is under 12 feet high. It must exclude rodents, wild birds, predators, dogs and cats and use sturdy wood, concrete, brick, metal or composite. Paper, plastic/tarps, tires, pallets, garage doors, canvas, glass block, bottles, bamboo, discarded/cast-off/secondhand or unintended materials are prohibited. Fences/enclosures must remain clean, sanitary, maintained and odor-free.
• State limited-access highway fences: Where GDOT limited-access fencing is affected by construction, it must be replaced in its original location with standard/in-kind fencing, six-foot chain-link or the type directed by GDOT. Replacement is required at each workday’s end or a temporary construction fence installed. Interstate limited-access gates require approval. Alternative nonstandard fencing is at least one foot inside the applicant’s property, maintained by the applicant and approved by GDOT; the limited-access fence remains in place.
• Work near overhead high-voltage lines: For covered fence work performed in pursuit of a trade or business, when people, equipment or long fence materials may approach within 10 feet of a high-voltage line, Georgia’s overhead-line law requires advance notice and the necessary safety arrangements. Its notice period is at least 72 hours, excluding weekends and holidays.
PRIVATE RESTRICTIONS
HOA covenants, private subdivision restrictions, deed restrictions, private architectural-review requirements, recorded private easements, conservation easements, agricultural agreements and boundary agreements operate independently and may be more restrictive. UDC Section 1-304 preserves valid recorded easements, covenants and deed restrictions to the extent they are more restrictive than the UDC.
Private restrictions differ from public subdivision requirements, utility/drainage easements, approved development conditions and public rights-of-way. City approval does not remove a separate private restriction.
REVIEW AND ENFORCEMENT CONTEXT
Fence issues are typically reviewed during permit or approval review when required, and through complaint-based code enforcement. Examples include:
• Permit and approval review: Engineered foundations, entrance monuments, retaining walls, ROW encroachments, pool enclosures and covered site work follow their respective approval processes.
• Height, materials and visibility: City review can address public-street frontage, the front building line, chain-link location/inserts, finished-side orientation, driveway sight areas and maintenance.
• Downtown and subdivision conditions: Applicable downtown design guidance, highway-corridor frontage treatment, subdivision curve protection, recorded easements and approved development conditions can affect the fence.
• Environmental site work: Covered excavation, grading, fill, stream-buffer disturbance, floodway encroachments, wetlands and stormwater facilities have their separate requirements.
• Pool and animal enclosures: The regulated enclosure’s height, construction, gate direction, locking and escape-prevention features are reviewed under the applicable pool or animal provisions.
• Utility and road conflicts: Meter access, underground utility responses, overhead-line conditions and public/state-road encroachments remain separate from the ordinary yard-fence standards.
USING THIS INFORMATION
This page provides general orientation on how residential fence rules are structured and applied within the City of Commerce, Georgia. Updated October 2026.
In addition to local fence rules, certain Georgia laws apply statewide. See Statewide Fence Laws in Georgia.
It is not legal advice and does not replace official ordinances, permits, approvals, surveys, or professional guidance. Rules and interpretations may change, and application may vary based on zoning district, site conditions, subdivision/land-development status, easements, rights-of-way, drainage or stormwater conditions, floodplain/floodway status, erosion/sediment or land-disturbance requirements, stream or state-water buffers, historic/design/special-district status, consolidated-government scope where applicable, pool-barrier use, utility-excavation requirements, road/highway conditions, and private restrictions such as HOA covenants or deed restrictions. Before purchasing materials or beginning construction, confirm current requirements and site-specific limitations with City of Commerce Planning & Development and any applicable private agreements. If this page conflicts with official ordinances, published guidance, adopted district guidelines, or direction from City of Commerce Planning & Development, the official sources control. For legal advice or legal interpretation, consult a licensed attorney.