FENCE RULES – DARDENNE PRAIRIE (CITY), MISSOURI

OVERVIEW

This page covers residential fences within the incorporated City of Dardenne Prairie, Missouri, in St. Charles County. County animal-control involvement does not make county zoning or building rules the city’s ordinary fence standards.

Dardenne Prairie requires a fence permit for fences or decorative posts at least thirty inches high. Side and rear property lines can be used under the stated street, easement and drainage conditions, while front yards and corner visibility receive special treatment. The code contains conflicting height provisions, so six feet six inches is not an unconditional citywide answer. Wood, synthetic materials and chain-link are recognized, with finished-face, matching-material and PVC quality requirements. Pools have detailed local enclosure and ladder rules alongside adopted construction codes. Rural R-1A livestock and chicken provisions have specific exceptions that differ from the general fencing rules. Updated November 2026.

Quick questionDardenne Prairie answer
Permit or approvalA fence permit is required for fences/decorative posts at least 30 inches high. Specified temporary and structural/safety exceptions retain their own conditions.
Typical fence height405.412 states 6 feet 6 inches; surviving 405.400 states under 6 feet 3 inches with its approval branch. The conflict and exceptions are detailed below.
Placement & property linesSide/rear lines can be used where they do not abut a street. Front setbacks, street-side projections, corner visibility, easements and drainage remain.
Common fence materialsWood: natural/treated wood recognized. Vinyl/PVC: synthetic materials recognized with quality standards. Chain-link: recognized, subject to special enclosure and matching requirements.
Important local conditionsFence rules may be further affected by conflicting height and R-1A provisions, multiple street frontages, easements, drainage, pools and ladders, PVC quality, chicken or livestock uses, floodplain conditions and approved plans.
Official local resourceDardenne Prairie’s official fencing standards

The table summarizes ordinary rules. The sections below preserve the conditions, exceptions and site-specific branches that determine how each requirement applies.

GOVERNANCE

Dardenne Prairie is a fourth-class city. The Board of Aldermen adopts city zoning and construction requirements within municipal limits. The City Code Enforcement Officer administers fence applications and compliance, and the City Engineer/authorized code officials have the stated construction and site-review functions. The city adopts its own 2021 International Building, Residential, Property Maintenance, and Swimming Pool and Spa Codes, with local amendments.

Title IV zoning takes priority over conflicting Title V requirements under 500.030; the local residential code also retains its specific/most-restrictive conflict provisions. Those rules do not themselves remove conflicting fence clauses within Title IV. The City Engineer administers the mapped floodplain program; land disturbance and approved development plans have separate controls. County Animal Control performs the animal functions identified in the city code, without importing unrelated county land-use rules.

PERMIT AND APPROVAL REQUIREMENTS

• Fence permit and application: Section 405.412(B) requires a fence permit before constructing a fence or decorative post at least 30 inches high. The owner or authorized agent applies to the City Code Enforcement Officer. The application identifies the property, owner/applicant/installer and contact information; a scaled plot plan shows the fence and gates; details give type, materials, height and approximate length. An applicable association letter addresses compliance with its restrictions. Municipal approval does not guarantee association approval.

• Approval, timing and inspections: The application must be complete, approved and accompanied by the full applicable fee. Work must start within six months and finish within one year or the permit expires; renewal is subject to review. Periodic and final compliance checks are authorized. The city’s residential-code amendment deletes the model seven-foot fence permit exemption, separate from the zoning fence-permit trigger.

• Temporary and structural/safety fencing: Temporary protective fencing during active excavation, construction or grading needs no fence permit. A structural/safety fence, such as fencing atop a retaining wall, has a fence-permit exception but must be shown as an improvement and receive city staff review/approval. Neither provision is a general retaining-wall construction permit exemption.

• Additional height: The 405.412 maximum can be exceeded by conditional use permit if the additional height does not further obstruct vision at streets, driveways, sidewalks or other traffic areas and the outside is attractively screened with plants. It can also be exceeded where necessary to comply with another current city ordinance. The separate 405.400 height provision and approval branch remain relevant.

• Floodplain development: A separate permit covers development/substantial improvement in the city’s mapped A/AE flood-hazard areas under Chapter 415, administered by the City Engineer. Floodplain approval is separate from the ordinary fence permit and does not mean every fence needs a floor-elevation certificate.

• Land disturbance: Chapter 412 uses a 5,000-square-foot city permit threshold. Its text allows work from 5,000 square feet to less than one acre to accompany a building application and describes a separate permit for work “more than” one acre. Its wording does not separately resolve the exact-acre boundary between those application routes. Exemptions for qualifying utility/right-of-way work, farming/landscaping/conservation, limited resodding, single/two-family gardening and emergencies retain the stated drainage/sediment conditions. The state construction program’s separate one-acre/common-plan threshold does not replace the city threshold.

• Neighborhood Development and legacy plans: Current 405.215 replaces the former Uptown area code with the Neighborhood Development district regime. Uses approved before September 15, 2021 retain their approved area/site plans; other properties follow the current district and other applicable city rules. A minor fence/screen change with equal opacity can be a City Engineer plan amendment. A legacy approved plan is property-specific, not a citywide fence standard.

FENCE PLACEMENT RULES

• Property lines and street frontages: Fences/posts must be on or within the property. Side/rear lines can be used where they do not abut a street. Section 405.412 prohibits fencing forward of the required setback and in the front-yard setback. On a lot with multiple street sides, fencing may project up to ten feet over the building line only on the street-adjacent side yard. Decorative posts below 30 inches can be in front if at least two feet from the line.

• R-1A front-yard conflict: Surviving 405.400(I) permits front-yard fences in R-1A, while 405.412 states the general front-yard prohibition. The published provisions supply both directions; Code Enforcement applies them to the actual district and proposed location. The fence-specific provisions are not replaced by generic accessory-building setbacks; the accessory-building definition excludes fences and retaining walls.

• Street-side gates and corners: Each fence side adjacent to a street needs a gate/opening at least three feet wide. Fences/posts cannot occupy the restricted intersection triangle or otherwise impede vehicular vision. The triangle and its potential enlargement are detailed below.

• Rights-of-way, easements and water: Placement in a state right-of-way requires a state permit. A fence in an easement can be removed by the owner or another authorized party without compensation. It cannot obstruct inlet/manhole covers, drainage patterns or swales, or natural flow on the property or adjoining properties. These provisions do not establish a universal fence setback from every easement or decide private ownership.

• Boundaries and survey markers: A fence location must respect the actual boundary and recorded rights. Missouri Section 60.355 prohibits knowingly moving, removing, defacing or destroying the listed public-land-survey corners, property markers, benchmarks and horizontal-control monuments, except by a registered land surveyor. It provides a class B misdemeanor classification, monument-restoration liability and the affected owner’s reasonable surveying-cost and attorney-fee remedy. A permit or utility mark does not determine a property boundary.

• Fence-post excavation notice: Missouri’s underground-facility law covers private-property excavation, including hand digging, augering, boring and driving. Except for its limited statutory exclusions, notice through Missouri 811 is required at least two working days and no more than ten working days before the expected start. The period starts at midnight following receipt; Saturdays, Sundays and state or federal legal holidays are excluded. Notice identifies the excavator and responsible person, contact details, expected start, depth, excavation type, trenchless work or explosives where applicable, and sufficient site/location information. The limited tillage and temporary-marker exclusions do not exempt structural post holes.

• Operator responses and second notice: Participating operators ordinarily respond within two working days unless an extended start is agreed. Work cannot begin before the scheduled date unless all facilities have been confirmed located. Either side can request a marking-clarification meeting within two working days; trenchless work also triggers available depth information. If an operator fails to respond to proper original notice, the excavator gives the prescribed second notice before starting. The operator then has two hours to mark or contact the excavator with its marking time. A second notice by 2 p.m. requires marking that working day; later notice requires marking by 10 a.m. the next working day. Excavation may begin only under the statute’s failure-to-mark-or-contact conditions, with required care continuing.

• Notice life and markings: The notice expires at 11:59 p.m. 21 consecutive calendar days from the work start date. Work can continue within the notified area while the notice and visible markings remain valid. Failure to begin within the stated ten-working-day period requires a relocate request before beginning. Unusable marks require a remark request with the original timing. Reasonable care to preserve marks remains required; failure of care or unnecessary repeat marking can create reasonable remarking-cost liability. Separately owned private lines are not a promise of universal locating service.

• Care near underground facilities: The ordinary approximate-location strip is the facility width plus two feet on each side; stated unusual conditions can require a wider designated area. Before work, the excavator determines best practices for confirming horizontal and vertical location in the actual site conditions, using hand or soft digging when possible. An incorrectly located or unmarked facility must be reported through the center; the operator must contact the excavator or correct the location within two hours. Notice compliance does not remove careful-and-prudent excavation duties or grant land-entry rights.

• Damage, emergencies and highway excavation: Facility damage, dislocation or disturbance, including trace wires, encasements and protective stakes, must be reported to the notification center. Pipeline contact/damage causing a hazardous-liquid or gas release requires an immediate 911 call. Damage cannot be concealed or repaired without the facility owner’s authorization. The narrow temporary sewer-emergency repair allowance after notice does not remove reporting. A genuine excavation emergency permits necessary work with reasonable precautions and notice as soon as practical; the operator must mark or contact within two hours and state its marking time if unable to mark then. Excavation in a state highway or its right-of-way separately requires the commission’s permit, subject to the railroad-right-of-way exception.

• Conditional division-fence rights: Missouri’s general and local-option partition-fence laws are alternative systems with their own livestock, allocation, notice, contribution and repair/removal conditions. The local-option system requires the statutory county election and adoption order and excludes counties with all or partial open range. These laws are not a rule that every neighbor pays half of an ordinary yard fence. General-law repair entry concerns repair of the owner’s division-fence portion, not a general access corridor. Removal consent and the separate cultivated-field notice/damage provisions retain their own conditions. Government approval does not settle those rights.

FENCE HEIGHT AND VISIBILITY RULES

• Conflicting ordinary height provisions: Section 405.412(C) states a maximum of six feet six inches for fencing, accompanying structures and decorative posts, with its exceptions. Surviving 405.400(I) requires fences under six feet three inches, unless security/screening is specifically approved by the Board as part of a conditional use, site plan or planned-unit development. These are materially different limits. The city’s permit review determines their application; neither figure is an unconditional permission for every lot.

• Intersection visibility: Section 405.400(F) prohibits a material vision obstruction in the triangle formed by intersecting street right-of-way lines and points 30 feet from their intersection, including equivalent points on private streets. The Board can enlarge the triangle for safety. Section 405.412 separately prohibits fences/posts in it or otherwise impeding vehicular vision.

• Local pool enclosures: Pools, spas and hot tubs need a continuous fence at least four feet high at its lowest point, measured from finished grade to the top, with a bottom clearance at most two inches. Gates open away from the pool and self-close/self-latch. The permanent fence must be complete within 15 days after pool installation/construction completion; the separate excavation-stage construction barrier begins earlier.

• Local aboveground pool walls and ladders: An inground pool or aboveground pool wall below 48 inches requires a separate four-foot fence measured outside. A wall at least 48 inches can be the barrier only without adding fencing/railings or other constructs on top to reach that height. A removable ladder alone is not enough: where the wall qualifies, its ladder access area still needs a four-foot fence and self-closing/self-latching gate. These local requirements remain alongside the model’s alternatives.

• Small water features and covers: The local small-feature exception requires BOTH depth less than 24 inches and surface area less than 250 square feet. Hot tubs/spas with an approved safety cover also have a local exception. The model’s powered-pool-cover alternative does not itself erase the separate local pool-fence requirements.

MATERIAL AND CONSTRUCTION LIMITS

• Materials, finished face and matching: Recognized materials include brick, stone/other masonry, synthetics, natural/treated wood, wrought iron, decorative aluminum and chain-link. Finished faces point outward and visible supports/structural components inward. Materials must be contiguous; new fencing must match existing material/design. If matching is impossible, such as a discontinued material, existing fencing must be removed or altered to match. Mixing fence elements, such as chain-link bridging two wood sections, is prohibited.

• PVC quality and the cross-reference: Section 405.412(D)(1)(a) requires minimum quality standards for synthetic/PVC fencing in both residential and commercial applications. The detailed quality clauses appear under “Commercial bufferyard fencing.” The general cross-reference remains applicable, while the narrower heading leaves a question about which commercial configuration/design details apply to a particular residential installation. City review applies that cross-reference and the detailed clauses to the proposal; the quality requirement cannot be disregarded merely because the detailed heading is commercial.

• PVC material and fasteners: The detailed clauses require rigid PVC, an extruded product adhering to ASTM standards, impact testing, ultraviolet stability, self-extinguishing/nonflammable material and a flash temperature of at least 900°F. Brackets/fasteners can be stainless steel, galvanized steel, brass or other outdoor material for weather/rust protection, including nuts, bolts, screws, washers, hinges and latches. Components must support themselves and resist bending/warping from heat, cold, wind and other external forces.

• PVC post and rail component schedule: The code says wall thickness should match component size and lists these cross sections/wall thicknesses, all in inches. Posts: 4 × 4 / 0.140; 5 × 5 / 0.135 standard or 0.170 heavy. Rails: 1½ × 1½ / 0.120; 1¾ × 3½ / 0.100; 3 × 3½ T-rail / 0.095; 2 × 6 hollow / 0.125; 1½ × 5½ ribbed / 0.090; 2 × 6 ribbed / 0.090; 3 × 3 / 0.110. The advisory wording is distinct from the mandatory strength requirements.

• PVC picket component schedule: Listed picket cross sections/wall thicknesses, in inches, are ⅞ × 1½ / 0.060 or heavy wall 0.090; ⅞ × 3 / 0.060; ⅞ × 6 ribbed / 0.060; and ⅞ × 7 tongue-and-groove / 0.060. Pickets can be ribbed/hollow, flat-sided or interlocking tongue-and-groove.

• PVC reinforcement, design and deviations: Posts should be reinforced, set to supporting depth, shown on the diagram, capped with complementary molded PVC and routed for rails. Bottom rails should have stiffener channels; steel/aluminum may be used, and rails should be routed for pickets. Gates should be reinforced to retain shape, fit and operation. Design/color should complement nearby structures, and pigment additives should not supersede material standards. Component sizes/shapes should not depart from the schedule unless needed for a custom installation, but any deviation requires schematic review and prior approval. These should/may clauses are not all worded as mandatory shall requirements.

• Wire and electric fencing branches: Barbed wire, razor wire, hardware cloth, wire mesh and electrified fencing are generally prohibited. Industrial security barbed wire needs a conditional use permit and at least five feet six inches of fence height under 405.412. Surviving 405.400(I) instead permits livestock barbed wire on R-1A and security wire above six feet with Board approval. R-1A electrified fencing under 405.412 is allowed only for keeping livestock, with an English “Electric Fence” sign on every side in letters at least four inches high. Buried invisible pet containment is excluded from that electric-fence definition. These specific branches do not authorize every residential wire fence.

• Condition and nonconforming fences: The owner must repair, paint, remove or attend to fencing that becomes unsightly or a safety/health/welfare menace. A notice normally allows 15 days, with hardship extensions at the officer’s discretion. Legal nonconforming fencing may remain if not replaced/relocated or structurally altered to extend, enlarge or intensify nonconformity; alteration requires current compliance. Adopted property-maintenance rules separately require sound, well-maintained fences/walls and protective treatment, with their decay-resistant-wood and oxidation-designed-surface exceptions.

• Pool construction fencing and cover scope: The adopted 2021 pool code requires an inground pool/spa site to have a construction barrier at least four feet high from excavation until completion of the permanent barrier. The model exceptions for lockable ASTM F1346 spa/hot-tub covers and powered ASTM F1346 pool covers remain subject to the independent local enclosure provisions. Outdoor pools/spas and indoor swimming pools otherwise use the following model barrier framework.

• Pool height, gaps and surface design: The model requires 48 inches above outside grade around the perimeter and for three feet horizontally outside. Bottom clearance is at most two inches over nonsolid ground or four inches over solid ground; a top-mounted barrier gap is at most four inches. Openings cannot pass a four-inch sphere. Solid surfaces have no climbing holds except normal masonry tolerances/joints. The city’s independent two-inch local bottom gap remains applicable to its enclosures.

• Mesh and member spacing for pools: Mesh follows manufacturer instructions: bottom gap at most one inch, no lifting over four inches or four-inch sphere passage underneath, attachment at least 45 inches, nonconductive deck sleeves and, where a hinged gate is used, compliance with the pool gate requirements. Mesh cannot sit atop an on-ground residential pool; it must remain at least 20 inches from the water edge. Horizontals less than 45 inches apart face the pool, with vertical gaps/cutouts at most 1¾ inches; at 45 inches or more, vertical gaps can be four inches but cutouts remain 1¾ inches. Chain-link openings are at most 1¾ inches, including slats fastened at both top and bottom to reduce openings to that size. Diagonal openings are at most 1¾ inches, with diagonals at most 45 degrees from vertical. Outside equipment such as pumps/filters/heaters must be at least 36 inches from the barrier.

• Pool gates and residential latch releases: Gates accommodate locking devices. Pedestrian gates open outward and self-close/self-latch; service gates remain locked when unused. Double/multiple gates secure one leaf and use a self-latching adjacent leaf. For residential release hardware accessed from outside and not self-locking, the release is at least 54 inches above finished ground/floor. Self-locking key/electronic/combination hardware has a residential maximum of 54 inches. A private-pool inside-only release is at least three inches below the gate top; openings within 18 inches of an inside release are no greater than ½ inch.

• Walls, alarms and model alternatives: Where a building wall provides direct pool access, doors/gates/screens and operable windows with sills below 48 inches above the interior floor require the listed UL 2017 audible alarm or an allowed protective alternative. Alarm deactivation is generally at least 54 inches; accessible-unit and nondwelling branches use 48–54 inches. Alternatives include the specified ASTM F1346 cover or approved equivalent protection such as self-closing/self-latching doors. The model permits qualifying manufacturer-approved 48-inch on-ground walls/top barriers and steps or ladders capable of being secured, locked or removed to prevent access unless separately enclosed by a compliant barrier, without resulting four-inch-sphere openings, but the city’s stricter wall-height and ladder-area enclosure rules remain.

• Natural pool boundaries and existing enclosures: A natural-water boundary requires prohibited public shoreline access and barrier extension at least 18 inches beyond the water edge; approved topography must give equivalent protection. Independently, adopted property-maintenance 303.2 covers private pools/hot tubs/spas with more than 24 inches of water, requiring a 48-inch outside enclosure and self-closing/self-latching gates/doors. A latch less than 54 inches above the gate bottom releases on the pool side. Gates must close/latch from six inches open; enclosure changes cannot reduce protection. Its safety-cover exception is for spas/hot tubs.

• R-1A residential agricultural uses: Personal horses require at least one acre, at one per acre, with stables at least 50 feet from property lines. Qualifying livestock uses require at least three acres, at one large animal per acre; commercial livestock requires at least ten acres. The stated agricultural-product/agritourism uses use a 20-acre condition. Those use-specific conditions do not waive the fencing branches above.

• R-1A chicken enclosures: Personal hens require an R-1A lot of at least one acre, with at most eight hens; roosters require at least five acres. The 2025 animal provision specifically requires a rear-yard wire-mesh/grid/chicken-wire enclosure at most six feet high, with at least ten square feet per hen. The coop needs at least four square feet per hen, at most 100 square feet. Coop/enclosure separation is ten feet from lines and 25 feet from another residence, with cleanliness, runoff and food protections. This specific newer mesh allowance differs from the general wire-mesh ban.

• Dangerous animals: Dangerous-animal confinement uses the stated secure indoor/secure-fence or locked-pen branches. A qualifying pen is at least five by ten feet, with a secure top and bottom or sides embedded at least 12 inches. Ordinarily it houses one animal, except a mother with young under three months. Entrance and enclosure-side signs, safe/sanitary conditions and zoning compliance remain. This is not a minimum pen size for every pet.

• Livestock at large: Section 270.010 prohibits an owner from permitting horses, mules, asses, cattle, swine, sheep or goats to run at large outside the owner’s enclosure. A person may restrain such stock, and an officer with police powers must do so on the stated view/notice conditions. Written notice to a known owner is due within three days, stating feeding/keeping compensation and claimed damages. The owner owes reasonable taking-up/keeping/feeding compensation and actual damage. For a public-road/highway accident, the owner has the statutory defense of proving the animals escaped through no fault or negligence of the owner. Unknown ownership or failure to compensate after notice leads to the stray-law process.

• Covered household sewage lagoons: Missouri’s onsite sewage regime includes single-family lagoons and excludes systems regulated under Chapter 644. Section 701.031 excludes a qualifying single-family residential lot of at least three acres, or the separate residential-lot branch of at least ten acres with no single-family onsite system within 360 feet of another onsite system and no more than one residence per ten acres in the aggregate. The exclusions do not cover the specified lots adjacent to lakes operated by the Corps of Engineers or a public utility. All system points must be more than ten feet from adjoining lines, without effluent trespass, surface/groundwater contamination or a scientifically determined nuisance. Construction, operation, major modification and major repair otherwise follow the statutory/rule regime. More restrictive local standards remain possible; acreage alone is not permission to construct a lagoon.

• Covered lagoon fence construction: Where 19 CSR 20-3.060(6)(D)15 applies, the pond must have a fence at least four feet high, complete before dwelling occupancy. Welded, woven or chain-link material must use wire no smaller than 14 gauge; cattle/hog panels may substitute with tee-post line posts. Posts must be pressure-treated wood or galvanized/painted steel, driven, tamped or concrete-set. Line posts must be no more than ten feet apart, corner posts properly braced, and sound construction must leave no bottom gaps. The fence must be no closer to the operating water edge than the berm center, measured at the three-foot operating water level. A properly hinged four-foot-high gate of comparable material needs an effective latch.

• Lagoon recommendations and local requirements: The state rule recommends, rather than mandates, line-post depth of 18 inches, corner-post depth of 24 inches, setback no greater than 30 feet from the water edge, and gate width of 36–48 inches. These “should” provisions differ from the mandatory fence, spacing, bracing, gate and occupancy requirements. The state Department of Health and Senior Services administers the statutory standards where local government has not adopted them; an independently adopted local ordinance can impose additional or stricter requirements.

• Licensed family childcare homes: For a licensed family childcare home, the outdoor play area must be on or adjoining the premises and accessible without hazards. Fencing is required where necessary against traffic, water or other hazards. For homes initially licensed after the rule’s effective date, and for new fences at existing facilities, the fence must be at least 42 inches high. Fences must prevent children from crawling/falling through or becoming entrapped.

• Licensed-home pools and animals: Swimming and wading pools at licensed family childcare homes must be fenced to prevent child access. For the rule’s initial-license cohort, the fence must be at least 42 inches with a locked gate. An aboveground pool may instead have that fence around its top and barricaded steps. Hazardous animals must be securely penned where children cannot reach them. These licensed-home rules do not replace other applicable local pool and animal requirements.

PRIVATE RESTRICTIONS

Recorded covenants, subdivision restrictions, homeowners-association architectural rules, private easements and enforceable boundary, maintenance or cost agreements can impose obligations separate from public requirements. Their actual wording and applicable Missouri law determine their reach; there is no universal private fence height or material rule for every property.

Government approval does not determine the property boundary, confer ownership of a shared fence, settle cost allocation or authorize interference with another person’s access. Public statutory partition-fence duties remain separate from private agreements. An existing fence’s age or position alone does not settle title, and a gate does not automatically legalize a fence across an easement.

REVIEW AND ENFORCEMENT CONTEXT

Fence issues are typically reviewed during permit or approval review when required, and through complaint-based code enforcement. Examples include:

• Permit and site review: Fence applications, expiration, applicable staff review of safety fencing, floodplain development, land disturbance and approved-plan changes.

• Location, dimensions and materials: Front/street-side location, corner visibility, conflicting height provisions, easements/drainage, finished faces, matching materials and PVC quality.

• Conditional enclosures and maintenance: Local and model pool barriers/ladders/gates, R-1A animal uses, chicken enclosures, dangerous animals, covered lagoons, licensed-home fencing and unsafe or altered nonconforming fences.

• Separate private matters: Association restrictions and boundary, ownership, easement or shared-cost disputes remain separate from public permits and code enforcement.

USING THIS INFORMATION

This page provides general orientation on how residential fence rules are structured and applied within the City of Dardenne Prairie, Missouri. Updated November 2026.

In addition to local fence rules, certain Missouri laws apply statewide. See Statewide Fence Laws in Missouri.

It is not legal advice and does not replace official statutes, ordinances, orders, permits, certificates, development approvals, applicable building-code requirements, surveys, recorded documents or professional guidance. Rules and interpretations may change, and application may vary with the identified municipality, including its actual municipal or county class, charter, adopted program or special district, and each function’s verified territory, the authority responsible for each issue, current code requirements and amendments, zoning and site conditions, subdivision or plat conditions, easements, rights-of-way, drainage and floodplain requirements, historic or design districts, pool use, agricultural or livestock conditions, fence ownership and shared-fence duties, excavation requirements, and private restrictions subject to Missouri law. Applicable requirements depend on the property’s actual facts and the respective authority of the identified offices. Private agreements and recorded rights remain separate from government approvals. If this page conflicts with controlling law, adopted regulations or official requirements, the controlling authorities govern.