FENCE RULES – UNIVERSITY CITY (CITY), MISSOURI

OVERVIEW

This page covers residential fencing within University City, Missouri, in St. Louis County. City zoning, building and property-maintenance rules govern the ordinary home-fence questions; historic districts, street rights-of-way, floodplain property and specialized enclosures can add conditions.

New fences require a building permit. The building-code exemption expressly includes replacement or minor repair of an existing section ten feet or less; the zoning provision separately describes replacement sections greater than ten feet and minor repairs less than ten feet. In required residential side and rear yards, the usual fence-height limit is six feet above grade, with a limited post allowance. Ordinary front-yard fences are generally prohibited, apart from the stated low landscaping protection and other exceptions. The all-yards fence exception and the accessory-use rear-setback language both matter to placement. Updated November 2026.

Quick questionUniversity City answer
Permit or approvalNew fences require a building permit. Building 105.2 exempts replacement or minor repair of an existing section ≤10 feet. Zoning 400.1300 uses greater-than-10-foot replacement and less-than-10-foot minor-repair wording; historic and other applicable approvals remain separate.
Typical fence heightSix feet above grade in required residential or HRO side/rear yards; posts may extend six additional inches, including ornament. Tennis, screening and district-specific exceptions have their own conditions.
Placement & property linesOrdinary residential fences belong in side/rear yards, with stated corner/through-lot and low front-yard exceptions. Section 400.1040 allows fences in required yards subject to Division 7; the accessory provisions also state a five-foot rear rule. The Zoning Administrator applies that overlap to the proposed line.
Common fence materialsWood: purpose-made fencing, subject to district design. Vinyl/PVC: the same general purpose-made standard, with historic compatibility restrictions. Chain-link: subject to the same standard; expressly addressed for tennis courts and certain Parkview fences. Pool-barrier openings are stricter.
Important local conditionsFence rules may be further affected by historic districts, the Olive corridor, visibility, accessory-use provisions, pools, retaining walls, grading, City trees, rights-of-way, mapped floodplain and private restrictions.
Official local resourceUniversity City Planning & Zoning

GOVERNANCE

University City is a charter, home-rule city. Its City Council adopts municipal rules. The Zoning Administrator administers zoning, the Building Commissioner administers the building and pool codes, and the Historic Preservation Commission reviews the work assigned to it. Planning & Zoning is the current public application and interpretation route; code text also uses the older department names Community Development and Planning & Development.

Chapter 500 adopts the 2018 International Building, Residential and Swimming Pool and Spa Codes, with University City amendments under Ordinance 7139, January 25, 2021. Chapter 240 separately adopts the 2012 International Property Maintenance Code with local amendments. The Director of Public Works and Parks administers the specified grading, public-right-of-way and floodplain functions; the City Forester handles City-tree and covered development-tree work. County territory alone does not substitute St. Louis County rules for these city adoptions.

PERMIT AND APPROVAL REQUIREMENTS

• New fences, replacement and repairs: Section 400.1300 requires a building permit for a new fence, replacement fence or replacement section greater than ten feet, and calls repairs to existing sections less than ten feet minor repairs not requiring permits. Building 105.2, applied to residential work by R105.2, expressly exempts replacement of a section and/or minor repairs to an existing section less than or equal to ten feet. Thus its exemption includes exactly ten feet; it does not exempt a wholly new ten-foot fence. Historic-district requirements and any other approval applicable to the work remain separate. Planning & Zoning is the official route if the scope includes more than one section or another regulated change.

• Fee and application route: The building fee schedule lists $35 for a new or replacement fence over ten linear feet. The city lists Fence Permit and Pool Enclosure Permit among applications available through MyGov; email and in-person applications are also available. Email applications and supporting plans, authorization forms and photos go to inspections@ucitymo.org. The city may take up to 48 hours to process the request before calling for payment. For a residential or nonresidential Building Permit application, the city requires four paper plan copies, with its limited printing option for no more than five pages at 11×17 inches or smaller. Planning & Zoning is on City Hall’s fourth floor, 6801 Delmar Boulevard, 314-505-8500.

• Retaining walls: Building 105.2 exempts walls not over four feet measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids. This building-permit exemption does not override district wall placement, visibility, historic review or an applicable guard requirement. IPMC 307.90 requires code-compliant guards where a wall’s grade difference exceeds four feet and it is closer than two feet to a walk, path, parking lot or driveway on the high side.

• Historic review: Sections 400.1610–1645 require permits for regulated historic-landmark or district work, subject to the particular district exemptions. The Zoning Administrator determines required Commission referral. Permit applications for structures within 300 feet of a historic district or properties on the National Historic Register also go for advice and recommendations. The stated exception concerns National Register properties in private subdivisions with their own construction review that are not city-designated landmarks or within city-designated historic districts. Commission recommendations generally are due within 45 days, or 30 days after a modified application; the applicant may attend and receives reasons for disapproval. The Administrator’s decision is appealable to the Board of Adjustment.

• Linden-Kingsbury review boundary: The official text contains a material difference: 400.1840(A)(3) prints 210 feet for fence/wall permit review in front of or within that distance of the front building line, whereas 400.1840(B) exempts such work more than 20 feet behind that line. Section 400.1850’s design boundary is also 20 feet, with the special north-property-line treatment below. Do not substitute 20 for 210 in the permit clause. The Zoning Administrator through Planning & Zoning is the precise official route to resolve which review applies to the proposed location. Ordinary like-material maintenance is separately exempted by 400.1840(B).

• Grading permits: Under 405.140, grading normally requires a separate site permit from Public Works and Parks, with an application and two copies of the required plan information. Exceptions include approved improvement construction; a foundation/basement for a permitted building, structure or pool; utility work; governmental public improvements; clearly incidental grading of less than five cubic yards and/or 1,000 square feet per acre that does not affect adjacent-property drainage; and right-of-way grading covered by an excavation permit. Exceptions retain the chapter’s land-development standards. The permit normally cannot exceed 120 days without approved phasing. Disturbance of at least one acre, including the stated common-plan condition, requires DNR permit evidence before local grading or improvement approval.

• Grading completion and inspections: Covered grading requires a cash guarantee for completion and long-term erosion control, based on an approved estimate. Public Works inspects commencement, rough grading, finished grading and permanent erosion controls; fill compaction must be monitored and certified by a registered soils engineer. A project substantially inactive 120 consecutive days is treated as delayed or abandoned. A completion order allows no more than 90 days; the city may use the deposit for corrective work and bill excess costs, with the stated unpaid-cost assessment/lien procedure. Unspent funds are refundable after satisfactory completion.

• Floodplain approval: Chapter 410 covers the mapped A/AE areas on the specified St. Louis County FIRM panels dated February 4, 2015, as amended and revised. Development in those areas requires a floodplain development permit; the Director of Public Works and Parks is Floodplain Administrator. The ordinary yard-fence rules do not displace mapped-site approval.

FENCE PLACEMENT RULES

• Side, rear and front yards: 400.1250 generally permits residential fences only in rear and side yards, except its express exceptions or an approved PD development plan. A front-yard wall or fence protecting landscaping may be no more than 18 inches above established grade and must meet visibility rules. This is not permission for a usual-height front privacy fence.

• Corner and through lots: On a corner lot a fence may stand between the dwelling’s side and the street right-of-way line, including on that line, but cannot extend beyond the front building line. On a through lot, a fence may occupy the street-adjacent yard that functions as the rear yard. Neither rule conveys public land or overrides the right-of-way permit rules.

• Required yards and the accessory rear rule: Section 400.1040(A)(1)(e) expressly permits fences in all required yards, subject to Division 7. At the same time, 400.1080(A)(6) lists fences, walls and hedges as accessory uses/structures; 400.1090(A)(3) states a five-foot rear-lot-line setback for accessory structures and uses, and (A)(6) retains a five-foot rear minimum for accessory structures on single-family detached/attached and two-family lots. Its (A)(4) expressly excepts fences, walls and hedges from the principal-structure front/side setback, with its stated cross-reference. The all-yards fence exception remains part of this chain and Division 7 still limits front fencing. The Zoning Administrator through Planning & Zoning applies these overlapping provisions to the proposed rear line; this page does not turn them into an unconditional zero-foot or universal five-foot fence setback.

• Pools, hot tubs and tennis courts: 400.1090(A)(7) separately requires private recreation facilities, including outdoor pools, hot tubs and tennis courts, to be at least five feet from any lot line and screened from adjacent residential property by a fence or dense planting. That facility setback and screening are separate from the pool-safety barrier requirements.

• Rights-of-way and excavation: A right-of-way permit is required for excavation or occupation of public right-of-way and for the stated fixed structures or objects there, apart from a U.S. mailbox. Public Works and Parks reviews the location, design and plans. Building 3315.3 additionally requires Public Works permits and inspections for excavation on or within three feet of public right-of-way. Its construction-site standards do not establish a general private-yard fence setback. The wireless-maintenance exemptions in 505.220 do not exempt a homeowner’s new fence.

• City trees and private development trees: A fence or pool accessory addition is expressly excluded from the development-project definition for the private-tree forestry-permit trigger. That exclusion does not authorize work on City trees: planting, pruning, spraying or removing a City tree/shrub requires City Forester approval and the specified permit, while mulching, watering and fertilizing do not. Unauthorized injury to City trees or roots, digging their root areas, or attaching wire, nails, rope or other devices is prohibited. A fence built as part of a separately covered new dwelling or special-use development retains that project’s tree-survey/preservation and replacement requirements.

• Drainage and ground changes: Under 405.510, exposed cut/fill embankments generally cannot be steeper than 3 horizontal to 1 vertical without stability certification by a registered soils engineer. Covered development must control short- and long-term erosion; graded areas are stabilized immediately, runoff is filtered and temporary measures stay until permanent controls are established. Grading over 20,000 square feet has the stated sediment-basin/trap/filter requirements. These conditions remain separate from a grading-permit exemption and do not authorize discharge onto a neighbor. IPMC 590 separately addresses nuisance drainage from regrading, downspouts, sump discharge and pool drainage.

• Floodway and flood-resistant construction: Encroachment in an adopted regulatory floodway requires the prescribed hydrologic/hydraulic demonstration of no increase in flood level. Before a floodway is designated in the stated numbered A/AE areas, proposed development plus existing and anticipated development cannot increase base-flood surface elevation more than one foot. Applicable construction must resist flood damage, be adequately anchored against flotation/collapse/lateral movement and protect utilities and sewage systems. These are mapped-development conditions, not universal yard-fence dimensions.

• Survey markers: Missouri Section 60.355 protects the listed public-land-survey corners, boundary markers, benchmarks and horizontal-control monuments from knowing removal, movement, defacement or destruction, with an exception for a registered land surveyor. The statute provides a class B misdemeanor classification, restoration-cost liability and the affected owner’s stated surveying-cost and attorney-fee remedy. A fence permit does not authorize moving a protected marker.

• Excavation notice: Fence-post excavation, including covered hand digging, augering or driving, is subject to Missouri’s underground-facility law. Section 319.026 requires notice to the notification center at least 2 working days, but not more than 10 working days, before the expected start. The statutory period begins at midnight following receipt; Saturdays, Sundays and legal holidays are not working days. Notice identifies the excavator, responsible person, location, expected start, depth and type of excavation, and the other required site/contact information. The notice service is Missouri 811. Utility locating does not establish property boundaries or grant permission to enter another property.

• Responses and an unanswered notice: Under Section 319.030, participating operators ordinarily respond within two working days unless an extension is agreed. Early excavation requires the law’s confirmation that all facilities have been located. If an operator has not responded after a proper original notice, the excavator must give the prescribed second notice before beginning. The operator then has two hours to mark or contact the excavator; a second notice received by 2 p.m. requires marking that working day, and a later notice requires marking by 10 a.m. the next working day. Only the statute’s failure-to-mark-or-contact conditions allow excavation after that process. An unanswered first notice is not immediate permission to dig, and careful work remains required.

• Ticket life and markings: The notice has an operational life ending at 11:59 p.m. 21 consecutive calendar days from the start date of work. Work may continue within the described area while the notice remains valid and markings remain visible. If work cannot begin within ten working days as described in the request, a relocate request is required before starting. Unusable marks require a remark request with the original notice timing. Excavators must reasonably preserve markings; unnecessary repeat marking caused by a failure of care can create cost liability.

• Care near facilities: The statutory approximate-location strip is ordinarily no wider than the facility width plus two feet on each side. When reinforced concrete, multiple adjacent facilities or other specified unusual conditions interfere with locating, the operator designates a wider approximate area to the best of its ability. Before excavation, the excavator determines best practices for confirming horizontal and vertical location in the actual site conditions; hand or soft digging is used when possible. An incorrectly located or unmarked facility must be reported through the notification center, and the operator must respond within two hours by contact or correct locating. The limited exclusions for specified tillage or temporary markers are not a general exemption for structural fence-post holes.

• Damage and emergency work: Damage, dislocation or disturbance of a facility or its protective items, including trace wires, encasements and protective stakes, must be reported to the notification center. Pipeline contact or damage causing a hazardous-liquid or gas release requires an immediate 911 call. The excavator must not conceal damage or attempt repairs without the facility owner’s authorization. Emergency temporary sewer repairs after notification are narrowly allowed to prevent further damage; they do not remove the reporting duty. A genuine excavation emergency permits necessary work with all reasonable precautions to protect facilities and notice as soon as practical. Within two hours of receiving the emergency notice, the operator must mark or contact the excavator with available information and, if unable to mark within that time, state when marking will occur. Separate Missouri Department of Transportation permission applies to excavation in a state highway or its right-of-way under Section 319.025, subject to its railroad-right-of-way exception.

• Livestock and division fences: Missouri’s partition-fence systems address their own livestock and adjoining-owner conditions; they do not require every residential neighbor to pay half of a decorative fence. The applicable general or local-option system determines contribution, notices, viewers, repairs and removal. County class alone does not identify that system. Under the general system, repair-entry rights concern repair of the assigned division-fence part; general removal requires all owners’ consent except the public-road opening exception. Separate statutory notice/damages provisions can apply to removal beside cultivated fields. Public permits do not decide those obligations.

FENCE HEIGHT AND VISIBILITY RULES

• Ordinary residential height: Under 400.1240, fences in required side or rear yards in residential and HRO districts may not exceed six feet above grade; posts may exceed that by no more than six inches including decoration/ornament. The requirement is explicitly tied to required yards, with screening, tennis/backstop/playground exceptions as stated. It is not a claim that every point on every residential parcel has a universal six-foot maximum.

• Intersection visibility: Under 400.1410, nothing may materially obstruct vision between 2½ and 10 feet above intersecting street-centerline grades inside the triangle bounded by street lines and a line joining points 12 feet from their intersection. Section 400.1290 applies the visibility provision to fences at or near street intersections or private access drives. The 12 feet is measured on street lines, not automatically from pavement edges; the provision does not state a separate private-drive numerical triangle.

• Tennis and nonresidential exceptions: A tennis-court chain-link backstop may reach ten feet if it is at least 20 feet from a property line abutting residential property. Nonresidential fences ordinarily have an eight-foot above-grade maximum apart from the stated sport exceptions. Nonresidential front yards, other than PA/IC, are limited to low masonry walls no higher than four feet, except integral columns; PA front-yard extensions are limited to playground/sport containment in parks. These do not grant an ordinary residential privacy fence extra height.

MATERIAL AND CONSTRUCTION LIMITS

• Wood: 400.1260(A) requires material designed and intended for fence installations, including decorative masonry such as brick, stone or textured/pigmented concrete. It does not individually list every wood product. Wood fencing remains subject to that purpose-made standard and applicable historic/design requirements.

• Vinyl/PVC: Vinyl and PVC are not individually named in the general fence-material clause; purpose-made fence material is the governing standard. A historic district’s compatible-material requirements can further limit a proposed product; general material suitability does not establish historic approval.

• Chain-link and hazardous materials: Chain-link is expressly addressed for tennis backstops and Parkview’s stated street-visible side fences. Elsewhere the purpose-made standard still applies; pool barriers have smaller-opening requirements below. Barbed wire, razor wire, tarp and similar material are prohibited in residential and PA fencing. Although 400.1260(B) permits barbed/razor wire above six feet in other districts, the separate citywide property-offense rule requires the lowest barbed strand used with another fence type to be at least 6½ feet above ground. Neither provision authorizes residential barbed wire or establishes permission for electric fencing.

• Repair and vegetation: Fences must be structurally sound, neat and clean. IPMC 302.7.1 requires good repair and materials matching the balance of the fence. Keep fence and foundation lines free of volunteer trees/shrubs; vegetation cannot block public travel or a driver’s view of an adjoining public way.

• Parkview fences and walls: In the city-designated Parkview Historic District, no fence, wall or hedge may be erected in front of the building line. Front retaining walls must be brick- or stone-faced and no more than two feet above the highest point of the sidewalk in front of the property. Street-prominent fences/walls on or behind the building line should be wood, stone, brick, brick-faced concrete, ornamental iron or dark-painted chain-link; all side fences are limited to six feet. Street-visible fence/wall work requires the prescribed Commission review and building permit. Ordinary compatible repairs or maintenance have the district’s stated exception; its standards preserve existing trust indentures.

• Linden-Kingsbury design: Section 400.1850(C)(3) prohibits fences, walls and retaining walls in front of or within 20 feet of the building line, except that they may be ten feet or more behind the front building line between 200/206 and 206/212 Linden. Street-visible fencing should be dark-stained or naturally weathered wood post-and-rail or evergreen hedge. Beyond 20 feet behind the line the standards do not regulate these walls/fences, except the north lines of 244 Linden and 469 North Hanley: there compatible screening for safety, privacy and Kingsbury traffic noise is allowed and need not be open post-and-rail. The separate 210/20-foot permit-text issue remains as described above.

• Clifford Row compatibility: The Clifford Row district concerns 6663, 6665, 6669, 6671 and 6675 Kingsbury Boulevard. Its referral and appearance standards apply to the specified new structures and exterior changes; street-visible exterior materials should be compatible with the original brick, stucco, wood and stone. Ordinary maintenance or repair without a design, material or outward-appearance change has the express exception. This is not a citywide ban on modern fence products.

• Olive corridor projects: For new development and substantial redevelopment along Olive Boulevard from Skinker to the east side of I-170, the Olive Boulevard Design Guidelines supplement other city requirements. Substantial redevelopment includes a 25% or greater floor-area increase, significant facade changes, historic restoration or significant site-design changes. The decorative-fence palette uses brick pedestals with sloped cast-stone caps, painted ornamental wrought-iron panels and adjacent evergreen shrubs. Required site-plan/design review and any MoDOT/County right-of-way approval remain project-specific; the street-furnishing illustrations are not a universal yard-fence height or setback schedule.

• Equipment and trash screening: Individual residential air-conditioning units are excepted from 400.1200’s outdoor-equipment screening. Single-family/two-family rubbish containers and containers adjacent to alleys are excepted from 400.1210’s screening requirements. Shared multifamily trash requires compatible sight-proof screening, not chain-link with opaque slats; nonresidential container screening has its own masonry/gate and six-to-eight-foot rules. These project/use conditions do not convert every home trash can into a fence-permit project.

• Existing pool enclosures: IPMC 303.2 requires private pools, ponds, hot tubs and spas containing water more than 24 inches deep to have a barrier at least 48 inches above finished ground on the side away from the water. Its trigger says containing water, not merely capable of holding it. Gates/doors must self-close/latch and positively close/latch when released six inches from the post. If a latch is below 54 inches above the gate bottom, its release must be on the pool side. Existing enclosures cannot be changed to reduce effectiveness. A compliant ASTM F1346 spa/hot-tub safety cover has the stated exception. IPMC 303.90 limits pedestrian gates to 40 inches, prohibits nonpedestrian gates and requires placement preventing climb-over from nearby permanent objects.

• New pool-barrier height and openings: The city’s 2018 ISPSC adoption and amendments govern covered aquatic-vessel work. Section 305.2.1 requires a 48-inch minimum barrier measured on the outside, away-facing grade around the full perimeter and for a three-foot horizontal outside zone. Bottom clearance is at most two inches over nonsolid ground or four inches over a solid surface; a barrier atop a pool/spa has at most four inches between its bottom and the pool top. Ordinary barrier openings cannot pass a four-inch sphere. Solid faces cannot form handholds/footholds except normal construction tolerances and tooled masonry joints.

• Pool-fence member spacing: For horizontal members spaced less than 45 inches between their tops, place them on the pool side and limit vertical-member gaps and decorative cutouts to 1¾ inches. With horizontal tops at least 45 inches apart, vertical gaps may be four inches but cutouts remain 1¾ inches. Chain-link openings must be at most 1¾ inches, including openings reduced by slats fastened at top and bottom. Diagonal openings are at most 1¾ inches and members no more than 45 degrees from vertical. Maintain a 36-inch outside clear zone from permanent climbable equipment/structures and at least 20 inches between the barrier’s pool side and water edge. University City deletes the mesh-barrier subsection; it should not be substituted for these retained rules.

• Pool gates and cover limits: The local 305.3 requires lock-capable pedestrian gates opening outward away from the vessel, self-closing/self-latching and no more than 40 inches wide. Local 305.3.4 prohibits nonpedestrian gates in R-2/R-3 occupancies; the IPMC’s existing-enclosure rule also prohibits gates other than pedestrian gates. Under 305.3.3, a release less than 54 inches from grade goes on the pool side at least three inches below the gate top, with no opening larger than ½ inch within 18 inches of the release. Double/multiple gates retain the specified secured-leaf/self-latching and ½-inch/18-inch protection, subject to those local gate restrictions. Local 305.1’s barrier exception is for spas/hot tubs with a lockable ASTM F1346 cover; it does not carry forward the model’s general powered swimming-pool-cover exemption.

• Dwelling walls and aboveground pool access: Where a dwelling/structure wall forms part of the barrier and a door or an operable window with its sill less than 48 inches above the indoor finished floor gives direct pool access, 305.4 requires the stated UL2017 warning alarm, a listed/labeled ASTM F1346 cover or approved equivalent protection. Alarm deactivation is normally at least 54 inches above the floor; accessible/Type A/Type B units use 48–54 inches. Under 305.5, the wall-only branch requires the pool wall bottom on grade, its top at least 48 inches above grade around the entire pool perimeter, wall compliance with 305.2 and manufacturer authorization for use as a barrier. In the top-mounted-barrier branch, the combined wall/barrier top must be at least 48 inches above grade around the entire perimeter, and both the wall and top barrier must comply with 305.2. The top barrier is installed to manufacturer instructions. Access ladders/steps must be securable, lockable or removable unless enclosed by a compliant barrier; resulting openings cannot pass a four-inch sphere. These alternatives do not remove University City’s other enclosure duties.

• Natural pool boundaries: Under 305.6, the shoreline exception requires no permitted public shoreline access and the required barriers extending at least 18 inches beyond the natural water’s edge. Natural topography under 305.7 requires governing-body approval and equivalent protection. Neither is a general exception for an unfenced backyard adjoining open land.

• Temporary construction fencing: Local Building 3315 applies to new construction and potentially hazardous work requiring separation from the public. Its site enclosure is chain-link at least five feet high, surrounding the project, equipment, tools and materials. Metal T-posts must be at least seven feet high, driven at least one foot below grade and placed at least every eight feet or as the Building Official requires. The designated construction entrance uses wood or metal posts embedded at least one-third of their height, with a gate and tightly strung fencing; the Official may require an accessible key lockbox. Approved plans show materials, location and gates. Fencing/barricades remain when a worker, owner or agent is absent. Erection may be no more than 30 days before construction; remove and restore the site within ten days after completion or within 30 days if construction has not commenced. No private-property encroachment is allowed; public-right-of-way encroachment needs written Public Works and Parks approval. Temporary excavations separately require three-foot orange mesh with T-posts at no more than eight-foot centers. Within ten feet of a public way, the stated excavation area must be covered with at least ¾-inch plywood, ¼-inch steel or similar protection; on or within three feet of right-of-way, Public Works permits and inspections apply.

• State onsite scope: Missouri’s onsite sewage rules include single-family lagoons. Section 701.031 excludes a qualifying single-family residential lot of at least three acres, or a residential lot of at least ten acres with no single-family residential sewage system within 360 feet of another onsite system and no more than one single-family residence per ten acres in the aggregate. The exclusions do not cover the specified lots adjacent to Corps of Engineers or public-utility lakes. Every system point must be more than ten feet from adjoining lines, with no effluent trespass, surface/groundwater contamination or scientifically determined nuisance. Section 701.047 preserves more restrictive local standards.

• Residential lagoon fences: Where 19 CSR 20-3.060(6)(D)15 applies, the pond fence must be complete before dwelling occupancy and at least four feet high. Welded, woven or chain-link material must use wire no smaller than 14 gauge; cattle/hog panels may substitute with tee-post line posts. Posts must be pressure-treated wood or galvanized/painted steel, driven, tamped or concrete-set; line spacing cannot exceed ten feet and corner posts must be properly braced. Sound construction must leave no bottom gaps.

• Lagoon geometry and gates: The fence location is no closer to the operating water edge than the berm center, measured with the water at the three-foot operating level. Three feet describes operating water depth, not a horizontal fence-to-water setback. The gate must be properly hinged, four feet high, of comparable materials and effectively latched. The rule recommends, rather than mandates, line-post depth of 18 inches, corner-post depth of 24 inches, a setback no greater than 30 feet from the water edge and gate width of 36–48 inches. These recommendations use “should,” while the fence, spacing, bracing, gate and occupancy requirements use mandatory language.

• Livestock on residential acreage: Section 270.010 makes it unlawful for an owner to permit horses, mules, asses, cattle, swine, sheep or goats to run at large outside the owner’s enclosure. Such animals may be restrained, and the sheriff or other police officer has the stated duty to restrain them. Within three days, the person restraining them must give the known owner written notice stating claimed feeding/keeping compensation and damages. The owner owes reasonable taking-up, keeping and feeding compensation and actual damages caused. For an accident on a public road or highway, the owner has the statutory defense upon establishing the animal escaped through no fault or negligence of the owner. Unknown owners or failure to compensate invoke the stray-law route. These duties are separate from partition-fence cost allocation.

• Licensed family childcare homes: Section 400.1330 lists day-care homes as uses that may qualify as home occupations, but the listing does not itself qualify or license a use. For an actual licensed family home, 5 CSR 25-400.085 requires hazard protection and play-area fencing where needed against traffic, water or other hazards. For the rule’s initially-licensed-after-effective-date or new-fence cohort, play fences are at least 42 inches and prevent crawling/falling through and entrapment. Pool/wading-pool fencing must prevent child access; the specified initial-licensing cohort requires 42 inches and a locked gate. An aboveground pool may use its top fence with barricaded steps. Hazardous animals must be penned beyond children’s access.

• State-park boundaries: For a boundary beside a state park or historic site, 10 CSR 90-2.070 provides participation to prevent livestock or commercial-game intrusion. A written Fencing Request Form and director/designee approval precede participation. Division inspection considers need, resource impacts, materials, cost and boundary location; a required boundary survey’s cost is shared equally. Written approval or denial is due within sixty days after receipt of the form.

• Park participation costs and construction: On approval, the division provides all fence construction materials as its statutory cost share, while the owner constructs and the owner and successors maintain. Construction must protect park resources and cannot alter elevations to drain wetlands or impound water on department land. The fence lies on the identifiable/verified boundary unless a written variance is approved.

• Park-boundary maintenance and removal: Maintenance on park land is limited to the rule’s brush/vine/regrowth work no more than three feet inside the boundary. Vehicles and equipment require facility-manager permission, as do herbicides affecting park vegetation. Overhanging branches may be trimmed at the boundary up to eight feet above ground. Removal requires written division consent except temporary repair removal. The division does not participate in fencing lands upon which poisonous crops are planted. The division also does not participate in costs where another law or judgment already requires the owner to fence.

• Abandoned family/private burial grounds: Section 214.131 protects qualifying cemetery fences and railings from knowing injury, mutilation, removal and the other stated damage, a class A misdemeanor. Its defined site has not been deeded to the public and has had no interment for at least twenty-five years. Section 214.132 separately grants reasonable ingress and egress for usual cemetery visits during reasonable hours when the qualifying site is wholly surrounded by private land without public access, with sheriff/chief county law-officer enforcement and preserved court disinterment/removal authority.

PRIVATE RESTRICTIONS

Recorded covenants, Parkview trust indentures, private subdivision architectural review, easements and enforceable fence ownership, cost or maintenance agreements can add obligations. The specific document and Missouri law control their scope. City permits do not establish a boundary, convey title, authorize trespass or require a neighbor to fund an ordinary decorative fence.

Missouri’s general and local-option division-fence systems have their own livestock, adjoining-owner, notice, viewer, repair, removal and contribution conditions. A city permit or county class does not select the system or make every shared fence a half-cost project. Fence age alone does not establish ownership. A gate does not necessarily cure obstruction of an easement.

REVIEW AND ENFORCEMENT CONTEXT

Fence issues are typically reviewed during permit or approval review when required, and through complaint-based code enforcement. Examples include:

• Permit scope: New fencing, replacement-section length, historic review, covered pool work and separately regulated grading or right-of-way work.

• Location and design: Required yards, the accessory rear-rule overlap, intersection visibility, historic district boundaries and the Linden-Kingsbury 210/20-foot review issue.

• Maintenance and safety: Fence condition, matching repairs, obstructing vegetation, pool-gate operation and climb prevention, and applicable specialized enclosures.

• Separate private matters: Boundary, title, covenant, easement and contribution questions remain separate from municipal permit approval.

USING THIS INFORMATION

This page provides general orientation on how residential fence rules are structured and applied within University City, Missouri. Updated November 2026.

In addition to local fence rules, certain Missouri laws apply statewide. See Statewide Fence Laws in Missouri.

It is not legal advice and does not replace official statutes, ordinances, orders, permits, certificates, development approvals, applicable building-code requirements, surveys, recorded documents or professional guidance. Rules and interpretations may change, and application may vary with the identified municipality, including its actual municipal or county class, charter, adopted program or special district, and each function’s verified territory, the authority responsible for each issue, current code requirements and amendments, zoning and site conditions, subdivision or plat conditions, easements, rights-of-way, drainage and floodplain requirements, historic or design districts, pool use, agricultural or livestock conditions, fence ownership and shared-fence duties, excavation requirements, and private restrictions subject to Missouri law. Applicable requirements depend on the property’s actual facts and the respective authority of the identified offices. Private agreements and recorded rights remain separate from government approvals. If this page conflicts with controlling law, adopted regulations or official requirements, the controlling authorities govern.